Main functions:

 

 

Turn your device on and off at desired humidity 

 

Settings are stored even when powered off. 

 

Humidity calibration correction   

 

High and low humidity alarm 

 
2.

 

Specifications:

 

 

Max Load: 10A (1100W @110V or 2200W @220V)

 

 

Humidity Accuracy: 1% 

 

Probe measurement range: 1%~100% RH 

 

Working temperature for the controller: -40°F~176°F / -40°C ~ 80°C 

 

Working humidity for the controller panel: less than 85% 

 

Working mode: Humidification mode OR Dehumidification mode 

 

Power supply: AC 110V ~ 240V, 50/60Hz 

 

Power consumption: less than 3W

 

 
3.

 

Indicator Instruction:

 

 

 
 
 

 

 

4.

 

Key Operation Instruction

 

 
SET: 

Press SET for 3 seconds to enter settings menu. In the settings menu, press SET once to enter a 

parameter setting. After specifying a value for a parameter, press SET once to go back to the menu. 

 

POWER: 

In setting process (SET indicator is ON), press POWER once to save and quit setting. When it’s not 

in working process (SET indicator is off), press POWER for 3 seconds to turn off the controller. Then press 

POWER once again to turn it on.

 

UP/DOWN: 

In setting process (SET indicator is on), press UP/DOWN to select parameter or adjust value of a 

parameter. 

Holding the button allows for rapid number adjustments.

 

Use UP/DOWN to check the Hb and Lb value. When it’s not in setting process (SET indicator is off), hold UP 

to check Hb (Higher bound of your desired humidity range), hold DOWN to check Lb (Lower bound of your 

desired humidity range).

 

Restore default setting:

 

When the controller is powered on, pressing POWER for 3 seconds to shut off the 

controller. Then press POWER once to turn on the controller. When the screen displays 888s, press SET and 

UP buttons at the same time until the display is back to normal reading. Then all settings will be restored to 

default. 

Alarm Switch:

 

The alarm function is disabled by default. It will be enabled if you specify a value for AL or 

AH. After alarm sounds, press any of the buttons to disable the alarm. 

Please note that in order to enable 

the alarm function again, you need to cut off the power and turn on controller again. 

 

SET indicator is on 

In setting process

 

SET indicator is off 

In control process

 

WORKING indicator is on  Supplying output power 

 

WORKING indicator is off  No output power

 

Содержание WH1436H

Страница 1: ...roller Manual NEW VERSION UPDATE The outlet has been updated from a universal outlet to a standard U S outlet The operation has been simplified for ease of use An expanded humidity control range has been implemented Emai bill 1226 163 com ...

Страница 2: ...turn it on UP DOWN In setting process SET indicator is on press UP DOWN to select parameter or adjust value of a parameter Holding the button allows for rapid number adjustments Use UP DOWN to check the Hb and Lb value When it s not in setting process SET indicator is off hold UP to check Hb Higher bound of your desired humidity range hold DOWN to check Lb Lower bound of your desired humidity rang...

Страница 3: ...ected humidity reaches 85 the controller turns off the humidifier NOTE The WH1436H can accurately controls turn on and turn off points However there might be overshooting It s not the WH1436H s fault You can consider changing the power of your humidifier to compensate for the overshooting effect Example 2 Control a dehumidifier Keep humidity between 35 and 38 Alarm sounds when the temperature exce...

Страница 4: ...lowing Lb to be greater than Hb or allowing Hb to be less than Lb To ensure Hb and Lb are specified correct value check it again after you quit setting Hold UP button to check Hb value and hold DOWN button to check Lb value on screen Further explanation about Compressor Time Delay PT The time delay is a way of over riding the humidity sensor so that regardless of detected humidity the output devic...

Страница 5: ...screen displays LLL This means the humidity is below the minimum value that this controller can measure E The screen displays HHH This means the humidity is over the maximum value that this controller can measure F It keeps beeping when the temperature reaches a certain level This is usually because the alarm has been set You can set AH 100 and AL 0 to disable the alarm function G Lower Bound Lb o...

Отзывы: