To clean the glass, use an ammonia based cleaner, locally available fireplace glass cleaners or Speedy White. Contact your 
dealer or Wilkening Fireplace Co. to obtain Speedy White glass cleaner. Take care not to apply the cleaner in a manner that 
it contacts painted areas or electroplated surfaces as discoloration may occur. Cleaner combined with the creosote will 
cause the gaskets to harden.

Use a soft cotton cloth or paper towel to remove the smoke/cleaner residue. Do not scrape the glass with razor blades 
or abrasive pads. This will damage the glass and may cause failure. Clean the glass only when the unit has cooled to room 
temperature.

Heat Output

The GranView fireplace generates the greatest BTU output when smaller, split fuel is used. The unit is operating at peak 
performance when the flames burn clean and clear.

This is a single burn rate appliance. Never close the combustion air supply when the fire is burning. The fire requires air for 
combustion and closing the air supply will exhaust the fire and create a buildup of gasses in the combustion chamber.

Front Clearance

Keep any combustible materials at least 3 feet away from the front of this fireplace. This includes furniture.

Refueling

When adding fuel to the fire it is important to crack open the doors for 15 seconds to clear any smoke. For optimum 
performance always maintain a hot firebox temperature. This is achieved by maintaining a hot coal bed and not stacking or 
overloading the unit with fuel. Failure to do so can create a smoldering, smoky fire. Maintaining a hot firebox will minimize 
smoke on the glass and creosote in the chimney.

Doors

WARNING:

 Fireplaces equipped with doors must be operated with BOTH doors fully open or fully closed. If 

the doors are partially open, gas and flame may be drawn out of the fireplace opening, creating risks of both 
fire and smoke damage. Doors may be cracked open on a cold start up or when refueling for up to 15 minutes. 

Door Options Available:

 Black Rectangular Tudor (part #GVBRT), Black Rectangular Prairie Style Tudor (part #GVBRTP), 

Black Arched Tudor (part #GVBAT), Nickel Rectangular Tudor (part #GVNRT), Nickel Arched Tudor (part #GVNAT) and 
Single Black Rectangular (part #GVBRS).

Содержание The GranView

Страница 1: ...Installation and Operation Instructions Keep these instructions for future use GranView Clean Burning Zero Clearance Fireplace The 800 367 7976 wilkeningfireplace com 9608 State 371 NW Walker MN 5648...

Страница 2: ...Home Installation Requirements 8 Doors for the GranView 9 Heated Air Ducting Options 9 Clean Face Kit 10 Facing 10 Blower Installation and Electric Wiring Diagram 11 Unit Diagrams 12 15 Installing th...

Страница 3: ...er gas logs gas starters or flame colorants Do not use coal or charcoal in this fireplace unit 6 Do not connect this appliance to a chimney flue that is serving another appliance 7 Never use gasoline...

Страница 4: ...e stop spacer and roof flashings may be placed directly on or next to normal construction materials The minimum recommended interior chase width is 55 The minimum chase depth is 24 The interior chase...

Страница 5: ...ducting of heated air Raised hearths must extend 16 in front of and 8 to each side of the fireplace opening Floor level hearths may have a minimum of a 16 noncombustible protrusion but 20 is recommen...

Страница 6: ...is employed Install and seal a storm collar to the section of chimney penetrating the flashing to prevent moisture from entering the chimney structure The roof penetration must meet the minimum cleara...

Страница 7: ...This is done to reduce the chance of smoke migrating from one chimney to the other The Chase Enclosure The chase is a framed structure created to encase the fireplace and chimney system A chase should...

Страница 8: ...h material to be installed on Use the Micore board provided to protect a raised combustible hearth structure or combustibles located below the finished hearth for floor level installations Any part of...

Страница 9: ...Co must be used for all top vent applications A minimum clearance of 6 must remain between the top of the top vent assembly and the finished ceiling The bottom of the top vent must be a minimum of 6 a...

Страница 10: ...variable speed 210 CFM 8 round inline blower This blower should be located directly behind the inlet vent housing and attached to the flexible plastic duct Make sure this blower is accessible for serv...

Страница 11: ...is mounted to the base of the fireplace at center 4 behind the lower grill using the wing nuts provided in the blower kit The blower assembly has two predrilled holes in the plate that slide over the...

Страница 12: ...5 to standoffs 43 unit face 1 4 3 18 11 3 16 48 50 5 37 4 2 Top standoff 24 to standoff 8 13 21 8 13 Side standoff 4 air supply 8 clean face inlet 9 14 7 12 9 18 7 4 Side standoff 4 heat duct connecti...

Страница 13: ...s Shown with optional top vent framing Finished frame opening 45 6 minimum to louver 11 11 Louver 55 Interior chase width recommended Outside air vent Create S trap Side mantel leg trim 16 6 16 8 2x4...

Страница 14: ...nts can go to front side or back of the fireplace chase Top vent kit 12 minimum if vents are installed in hearth Upper steel baffle with holes Baffle support tabs Baffle 7 Air tubes Angle refractory p...

Страница 15: ...add 5 to total width for this upstairs fireplace If ducting to the left no additional width is required 17 inch offset shown 12 raised hearth shown 12 raised hearth shown 30 degree no offset support...

Страница 16: ...onnect them on the top center edge Place the four side pieces in place part 4 start by sliding the front ones in position before each back one Place the refractory panel part 5 over the top edge of th...

Страница 17: ...added to the installation do so now see page 11 for the on board blower Reinstall the lower grill 8 Install the doors See page 9 9 Finish facing of the fireplace and hearth area See page 10 11 10 Ins...

Страница 18: ...ed position Verify that the doors are fully closed summon the fire department alert your family of the possible danger and evacuate the premises A chimney fire is a serious condition that may result i...

Страница 19: ...ill exhaust the fire and create a buildup of gasses in the combustion chamber Front Clearance Keep any combustible materials at least 3 feet away from the front of this fireplace This includes furnitu...

Страница 20: ...nual inspection before the first fire of the year to verify that all components are working properly and that the chimney is ready for use We recommend contacting a Certified Chimney Sweep or your dea...

Страница 21: ...me With the advent of tighter homes it has become apparent that the lower levels of these homes will have a lower pressure level than the upper areas This is caused by the stack effect of the house th...

Страница 22: ...lure to use or install this fireplace as stated in this manual will void all warranties and may create a dangerous condition which may result in loss of property or life Never plug the outside air sup...

Страница 23: ...cludes enough for entire door assembly GVDGK Glass Panel for Rectangular Tudor GVRCGTD Glass Panel for Arched Tudor GVACGTD Glass Panel for Rectangular Single Door GVRCGSD Removable Log Retainer GVLR...

Страница 24: ...Wilkening Fireplace Co Walker Minnesota Visit our website at wilkeningfireplace com...

Отзывы: