background image

 

 

 

 

To Complete:

 Build a brick or concrete enclosure around fireplace, and then apply the finishing 

materials, such as tiles, stones, bricks, granite or marble. 

 
Chimney System: 

 

 

Chimney pipe diameter will vary depending on the length of the entire chimney.   

 

Contact Mechanical Sales for appropriate chimney system: (678)461.5997 

 

We don’t recommend building chimney with bricks or blocks. Use metal chimney pipe. 

 
1.

 

Attach chimney pipe anchor plate to top of hood assembly. Seal base plate with high 
temperature stove cement. 

2.

 

Seal all gaps with high temperature stove cement. 

3.

 

In the case of using round tubing directly into the hood, grout gaps around pipe with refractory 
grout leaving no remaining space between the tube and the chimney pipe.  

4.

 

Place approved spark arrestor chimney cap on top of chimney pipe (check local codes). All 

chimneys systems to be UL listed for solid fuel burning. Contact mechanical sales for your chimney 
system. 678 461 5997  

5.

 

Finish building a wall of bricks or blocks.

 

 

 
 

 Surround Suggestion:

 First build a wall of common bricks or blocks and Type S mortar as per local 

codes, or use metal studs and cement board .Apply stone or brick veneer. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Fireplace

Страница 1: ...Fireplace Owner s Manual 800 579 2797 323 255 6578 Fax 323 306 5689 Info wildwoodovens com www wildwoodovens com 5050 La Roda Ave Los Angeles CA 90041 ...

Страница 2: ...Fireplace Assembly Instructions Toll Free Help Line 800 579 2797 Kit Contents 3 base pieces 3 side wall pieces 3 flue pieces 1 Damper 2 Tubes Fireplace Cement ...

Страница 3: ...level with top of base A 2 Place base piece B piece without refractory bricks on base A Check for level and trace outline of the base B Remove piece B and apply a thin coating of mortar on the area you have traced Use the same mortar mixture see page 1 to attach Make sure base is level 3 Place fireplace side walls C and back wall D over base B Do not use mortar in these joints ...

Страница 4: ...eces Place the base of the hood E on top of side walls C making sure it is level and aligned with side walls 5 Install the Damper in the hood s base center by leaving equal distances on each side To open and close the register pull the lever forward and backward 6 Tighten the bolts on the damper ...

Страница 5: ...amper to make sure it opens and closes easily 8 Place hood piece G over piece F in the same fashion as the last Place the 2 refractory brick bases B2 and B3 over base B without mortar 9 Grout all internal joints of the fireplace with the refractory grout supplied with the kit ...

Страница 6: ...th high temperature stove cement 2 Seal all gaps with high temperature stove cement 3 In the case of using round tubing directly into the hood grout gaps around pipe with refractory grout leaving no remaining space between the tube and the chimney pipe 4 Place approved spark arrestor chimney cap on top of chimney pipe check local codes All chimneys systems to be UL listed for solid fuel burning Co...

Отзывы: