counter is cleared in any time.
Event Counter
Three digits LCD in the center of the lower are the event counter which allow you to know how many motion
records that up to 999 events for a trail period history. If you want to renew the counter anytime, simply to
press and hold the OK/DEL button until LCD become blinking, then it will resume to [000].
Battery Icon
Two icons are for difference battery groups. The Bat-icon on the upper corner of right is represented for
motion sensor power. The second on the right is for camera power. All Bat-icons will indicate three status as
below:
GOOD: Battery Icon show with solid.
LOW: Battery Icon is half blank.
BAD: Battery icon is totally blank.
Note: You have to replace all batteries in camera section or motion sensor section for new one
completely when either camera or motion power are BAD. Do not try to replace some of them
only. Important:
Since this unit detects batteries becoming too weak and the blank battery icon for
IR flash does appear, the unit will stop taking any night pictures or video but still will take pictures or
video at day time.
Walk-Test / Sensitivity Adjustment
This is main PW switch in the bottom of cabinet. The
DISTANCE
dial on inner panel is used for adjusting
sensitivity of the motion sensor. By turning the dial to the right, sensor sensitivity is set to the Max to detect
animal over 40 feet away. You may reduce the detection distance for taking with a larger animal target in a
picture.
Walk-Test feature
is used to verify the detection range and pointing zone before placing it in the
field. After hanged the unit on a tree, push the PW switch to Walk-TEST. The Walk-Test LED will light up last 1
minute to warm up. (A radar icon with TEST alert is remaining blinking during Walk-Test mode if you are
viewing the insite panel). Then, Walk-Test Light will goes off and will alert with 3 times flash once you will be
detected in front of the device. Now you try to go far away to check how long the PIR motion sensor will still
see you. The camera does not take any picture during this test process.
Note: The system will resume back to normal ON DUTY mode automatically after 3 minutes (Time-Out) since
the last triggered detection of walk-test to avoid user may forget to push the PW switch back to ON before he
left.
PW-ON Mode
Once the PW-SW is pushed to ON mode, the unit will begin to warm up for 20 seconds, then start to detect
motion for taking pictures/ Video. When an animal or human is detected, an event will be recorded and the
camera will shot immediately. If you want to stop the device operation, simply slide it to OFF.
OFF Mode
Slide the PW to the center position turn the system power OFF. All pictures and current settings will be
remained at this mode and internal real time clock will still run. Note: Remember to remove all batteries out if
this camera will be no longer to use.
Turbo Shot/ Time Lapse
Push the knob to
Fast Trigger
mode, the DC will be set for fast shooting. In this mode, capture speed will be
more than 2x faster than setting in the BAT-Save while a motion is detected. Setting of BAT_SAVE will be only
ideal for extending battery life. Also, the Time Lapse operation will works only at this mode. (See more
paragraphs about the
Setting for Time Lapse Operation
below)
Setting for CAMERA / Operation
Description for Camera Operation Keys
SHOT / PREVIEW / PIC/VIDEO / DISPLAY / MENU (Center Key) /Navigation Disk
CAM-PW (Camera Power Button)
Before programming for the camera, be sure Main Power switch at ON position and camera is not working