23
SLIDE CONTROL OPERATION
1.
Push the control lever to the le to the IGN symbol . The spark generator should cause a repeve spark at the
pilot and the pilot and main burner should ignite. If the pilot does not light aer 10 seconds then slide the control
lever to the right towards the OFF symbol and wait for 3 minutes.
2.
Once the pilot and main burner are lit keep the control lever held In this posion for up to 15 seconds. Before
releasing the lever give a firm push to the le to ensure the valve is engaged.
3.
Now slowly release the control lever to the symbol, the pilot should remain lit and the burner will be in the
LOW seng. If it goes out, slide the lever to the OFF symbol and wait for 3 minutes. Then return to step 1.
4.
To set the appliance to the HIGH seng, move the control lever to the right to the flame symbol. A stop will be
felt at this posion.
5
It is also possible to adjust the control knob between the and the flame symbols to achieve mid sengs.
6
To turn the fire off, push the lever to the right to the symbol to turn off.
IMPORTANT NOTE: Should the spark generator fail to provide a spark at the electrode it may be that a small amount of
soot has fallen from the fuel bed onto the pilot assembly, causing a short circuit. If this is the case, ensuring the
appliance is off and cold, this area can be cleaned with the thin nozzle from a vacuum cleaner—see previous pages to
remove trim / glass and logs. Alternavely check the baery is in good condion—the baery access cover is at the base
of the appliance just le of centre and can be accessed by removing the front trim and marble access cover.
When lighng slide control appliances it should be noted that the main burner will light at low rate during the
pilot ignion process.
OPERATING INSTRUCTIONS