background image

  1

  2

  3

  4

  5
  5A

  5B
  6

  7

  8
  9
10

11

12
12A

13

14

15

16

17

18
19
20
21
22
23
24
25
26
27
28
29
30

31

32

33

34

WC-5459
GEM-6
WC- 37121*
WC-  844-101*
WC-39442
WC-39415
WC-39414
WC-3417
WC-29050
WC-58037-101
WC-  847*
WC-2402P
WC-37122*
WC-  442
WC-  441
WC-1825
WC-8559
WC-8591*
WC-3528
WC-62030
WC-37008
WC-5502-01*
WC-4382
WC-5310*
WC- 934-04*
WC- 522*
WC-43055
WC-5231*
WC-1438-101*
WC-3765L*
WC-1501
WC-  102*
WC-5350*
WC-37176*

WC-13335

WC-37132*
WC-2977-101K*

COVER, TOP WRAP
FILTER, 500/PKG (USE WITH WC-3417)
KIT, DUMP VALVE BREW LEFT
VALVE, BY-PASS W/RESISTOR
LABEL, UCM OVERLAY TP2T TWIN 3-BATCH CURTIS
LABEL, UCM OVERLAY TWIN 2-BATCH CURTIS
LABEL, UCM OVERLAY TWIN 1-BATCH CURTIS
BREW CONE,ASSY W/SPLASH POCKET BROWN COF
SPRAYHEAD, ADVANCED FLOW
COVER, CENTER WRAP TP 90º
VALVE, WATER INLET 2GPM 120V 10W
ELBOW, 3/8”FL x 3/8” NPT PLATED
KIT, DUMP VALVE BREW RIGHT
SOLENOID, LOCK BREW CONE RIGHT /LEFT 120V
SOLENOID, LOCK BREWCONE LEFT (OLDER UNITS)
FAUCET, ASSEMBLY HOT WATER TP2S
RELAY, SOLID STATE W/INTEGRATED HTSNK
CAPACITOR
LEG, 4” ADJUSTABLE 3/8-16 THRD ITALIAN STYLE
TANK, COMPLETE TP2T ULTEM FITTINGS
KIT, TANK LID ROUND
KIT, PROBE, ASSY WATER LEVEL
GUARD, SHOCK HEATING ELEMENTS
TUBE, 5/16” I.D. X 1/8” SILICONE
ELEMENT, HEATING 2.5 KW 220V W/JAM NUTS
THERMOSTAT, RESET
GUARD, SHOCK RESET THERMOSTAT
COMPOUND, SILICONE
SENSOR, HEATING TANK
KIT, VALVE REPAIR USE ON WC-825 & WC-826
FUSE HOLDER
SWITCH, TOGGLE 125/250 VAC RESISTIVE
TUBE, ½ ID x 1/8W SILICONE
KIT, UCM & LABEL INSTRUCTIONS THERMOPRO
HARNESS ASSY, COMPLETE TP2T10 (NOT SHOWN)
KIT, DUMP VALVE WC-820WC-821,WC-844
KIT,SPRAYHEAD FITTING PLASTIC

ITEM №

PART №

DESCRIPTION

* RECOMMENDED PARTS TO STOCK.

ILLUSTRATED 

PARTS LIST

THERMOPRO

TWIN BREWER

TP2T

5

Содержание ThermoPro Single

Страница 1: ...ernational requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit so that the machine can be moved for cleaning underneath the unit...

Страница 2: ...eaches the setpoint 200 F unit is at brewing temperature THERMOPRO WILBUR CURTIS WILBUR CURTIS WILBUR CURTIS FILLING WILBUR CURTIS HEATING WILBUR CURTIS READY TO BREW 2 BREWING INSTRUCTIONS 1 Brewer s...

Страница 3: ...ramming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NOTE ThermoPro Programming...

Страница 4: ...E 27 A 25 26 1 2 34 3 4 5 6 7 8 13 14 15 16 9 10 11 12 17 18 19 20 21 22 23 24 28 29 30 31 B 33 4 PARTS DIAGRAM THERMOPRO TWIN BREWER TP2T...

Страница 5: ...NTER WRAP TP 90 VALVE WATER INLET 2GPM 120V 10W ELBOW 3 8 FL x 3 8 NPT PLATED KIT DUMP VALVE BREW RIGHT SOLENOID LOCK BREW CONE RIGHT LEFT 120V SOLENOID LOCK BREWCONE LEFT OLDER UNITS FAUCET ASSEMBLY...

Страница 6: ...6 PARTS DIAGRAM THERMOPRO SINGLE BREWER TP2S 26 3 12 2 6 28...

Страница 7: ...W COVER CENTER WRAP VALVE WATER INLET 2GPM 120V 10W FUSE HOLDER W 5A FUSE KIT DUMP VALVE BREW RIGHT KIT DUMP VALVE WC 820WC 821 WC 844 FAUCET ASSY HOT WATER TP2S 2T RELAY SOLID STATE 40A W HEAT SINK H...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...an water removing any residual detergent d Dry the area c Attach the sprayhead Cleaning the Thermoserver 1 Drain coffee from the server 2 Fill the liner with a mild detergent solution and let it stand...

Страница 11: ...Page Intentionally Left Blank 11...

Страница 12: ...l and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to e...