Product Warranty Information

The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use.  The following limited 

warranties and conditions apply:

Years, Parts and Labor, from Original Date of Purchase on digital control boards

.

Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing.

Year, Labor, from Original Date of Purchase on all electrical components, fittings and tubing.

Additionally, the Wilbur Curtis Company warrants its Grinding Burrs for Forty (40) months from date of purchase or 40,000 pounds of coffee, 

whichever comes first.  Stainless Steel components are warranted for two (2) years from date of purchase against leaking or pitting and replace

-

ment parts are warranted for ninety (90) days from date of purchase or for the remainder of the limited warranty period of the equipment in which 

the component is installed.

All in-warranty service calls must have prior authorization.  For Authorization, call the Technical Support Department at 1-800-995-0417.  Effective 

date of this policy is April 1, 2003.

Additional conditions may apply.  Go to 

www.wilburcurtis.com to view the full product warranty information.

CONDITIONS & EXCEPTIONS

The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replace

-

ment parts installed on Curtis equipment that have not been purchased from the

Wilbur Curtis Company, Inc.  The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty 

does not cover and is void under the following circumstances:

1)  Improper operation of equipment:  

The equipment must be used for its designed and intended purpose and function.

2)  Improper installation of equipment: 

 This equipment must be installed by a professional technician and must comply with all local electrical, 

mechanical and plumbing codes.

3)  Improper voltage:  

Equipment must be installed at the voltage stated on the serial plate supplied with this equipment.

4)  Improper water supply:  

This includes, but is not limited to, excessive or low water pressure, and inadequate or fluctuating water flow rate.

5)  Adjustments and cleaning:  

The resetting of safety thermostats and circuit breakers, programming and temperature adjustments are the 

responsibility of the equipment owner.  The owner is responsible for proper cleaning and regular maintenance of this equipment.

6)  Damaged in transit:  

Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the carrier. 

7)  Abuse or neglect (including failure to periodically clean or remove lime accumulations):  

Manufacturer is not responsible for variation 

in equipment operation due to excessive lime or local water conditions.  The equipment must be maintained according to the manufacturer’s 

recommendations.

8)  Replacement of items subject to normal use and wear:  

This shall include, but is not limited to, light bulbs, shear disks, “0” rings, gaskets, 

silicone tube, canister assemblies, whipper chambers and plates, mixing bowls, agitation assemblies and whipper propellers.

9)  Repairs and/or Replacements 

are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal 

use.  All labor shall be performed during regular working hours. Overtime charges are the responsibility of the owner.  Charges incurred by 

delays, waiting time, or operating restrictions that hinder the service technician’s ability to perform service is the responsibility of the owner 

of the equipment.  This includes institutional and correctional facilities.  The Wilbur Curtis Company will allow up to 100 miles, round trip, per 

in-warranty service call.

RETURN MERCHANDISE AUTHORIZATION:  

All claims under this warranty must be submitted to the Wilbur Curtis Company Technical 

Support Department prior to performing any repair work  or return of this equipment to the factory.  All returned equipment must be repackaged 

properly in the original carton. No units will be accepted if they are damaged in transit due to improper packaging.  

NO UNITS OR PARTS WILL 

BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).  RMA NUMBER MUST BE MARKED ON THE CARTON 

OR SHIPPING LABEL.  

All in-warranty service calls must be performed by an authorized service agent.  Call the Wilbur Curtis Technical Sup

-

port Department to find an agent near you.

Содержание ThermoPro Single

Страница 1: ...ernational requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit so that the machine can be moved for cleaning underneath the unit...

Страница 2: ...eaches the setpoint 200 F unit is at brewing temperature THERMOPRO WILBUR CURTIS WILBUR CURTIS WILBUR CURTIS FILLING WILBUR CURTIS HEATING WILBUR CURTIS READY TO BREW 2 BREWING INSTRUCTIONS 1 Brewer s...

Страница 3: ...ramming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NOTE ThermoPro Programming...

Страница 4: ...E 27 A 25 26 1 2 34 3 4 5 6 7 8 13 14 15 16 9 10 11 12 17 18 19 20 21 22 23 24 28 29 30 31 B 33 4 PARTS DIAGRAM THERMOPRO TWIN BREWER TP2T...

Страница 5: ...NTER WRAP TP 90 VALVE WATER INLET 2GPM 120V 10W ELBOW 3 8 FL x 3 8 NPT PLATED KIT DUMP VALVE BREW RIGHT SOLENOID LOCK BREW CONE RIGHT LEFT 120V SOLENOID LOCK BREWCONE LEFT OLDER UNITS FAUCET ASSEMBLY...

Страница 6: ...6 PARTS DIAGRAM THERMOPRO SINGLE BREWER TP2S 26 3 12 2 6 28...

Страница 7: ...W COVER CENTER WRAP VALVE WATER INLET 2GPM 120V 10W FUSE HOLDER W 5A FUSE KIT DUMP VALVE BREW RIGHT KIT DUMP VALVE WC 820WC 821 WC 844 FAUCET ASSY HOT WATER TP2S 2T RELAY SOLID STATE 40A W HEAT SINK H...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...an water removing any residual detergent d Dry the area c Attach the sprayhead Cleaning the Thermoserver 1 Drain coffee from the server 2 Fill the liner with a mild detergent solution and let it stand...

Страница 11: ...Page Intentionally Left Blank 11...

Страница 12: ...l and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to e...