Страница 1: ...01 08 2021 53 1082 Installation and User s Manual made by WIKING LUMA 6 WIKING LUMA 4 WIKING LUMA 5 WIKING LUMA 3 WIKING LUMA 2 WIKING LUMA 1 EN...

Страница 2: ...The Clean Air Act 1993 and Smoke Control Areas 8 Installation 9 Firing manual wood 15 Firing in general 18 Maintenance 19 Declaration of Performance 21 Product informaiton EcoDesign 22 Trouble Shootin...

Страница 3: ...Page 3 of 24 pages A1 A2 B1...

Страница 4: ...Page 4 of 24 pages B2...

Страница 5: ...Page 5 of 24 pages E1 E2 C...

Страница 6: ...Page 6 of 24 pages D F...

Страница 7: ...Page 7 of 24 pages G...

Страница 8: ...an Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The HWAM Luma stoves detailed below have been recommende...

Страница 9: ...sh combustion air to the room where the stove is to be installed The woodburning stove uses approx 9 20 m3 of air per hour A window that can be opened or an adjustable air valve will be sufficient It...

Страница 10: ...ms of the size and thickness of a non combustible floor covering the floor in front of the combustion chamber opening Ask your WIKING retailer for assistance The combustion chamber opening is 35 7 cm...

Страница 11: ...ING Luma 1 without a pedestal WIKING Luma 2 without a pedestal are pla ced directly on the floor a non flammable construction of minimum 42 5 cm is required in front of the stove Remember to pay atten...

Страница 12: ...in the top plate of the stove if the stove is connected to a back smoke outlet Changing the Smoke Outlet from Top Outlet to Back Outlet WIKING Luma 5 Luma 6 drawing F Proceed as follows to change the...

Страница 13: ...from the wood you add to the stove as the warm smoke is not simply sent out through the chimney Fitting the loose parts Before the stove is installed you must ensure that all loose parts are fitted c...

Страница 14: ...d t is possible to connect several devices to the same chimney However it is important to first check the applicable rules Chimney sweeping To prevent the risk of chimney fires the chimney must be cle...

Страница 15: ...of wood such as ash beech oak and elm are generally not that easy to light up In addition they burn more slowly and give off more embers Light types of wood such as birch maple spruce and pine are mor...

Страница 16: ...layer of kindling Light up the fire lighters and close the stove door If condensation forms on the glass keep the door ajar for a little while and close again When all of the wood has caught fire the...

Страница 17: ...Automatic might be damaged Only open the door when lighting the stove refuelling it and cleaning it Never leave a stove before there are lasting flames in the wood after firing Stoking When there are...

Страница 18: ...wood not heat up the room The fire should only be stoked with a little wood at a time You achieve the best combustion by starting up a fire often and using only a little wood If you use too much fire...

Страница 19: ...king hooks All service checks must be performed by an authorised fitter Use only original spare parts Inside cleaning Before chimney sweeping can be performed the air control lever must be set to its...

Страница 20: ...eler is controlled The starting point on a cold stove is about 100 above horizontal It should feel easy going and bouncy when you push it no matter if the stove is cold or hot Mount the rear plate and...

Страница 21: ...Page 21 of 24 pages Declaration of Performance The DoP can be downloaded from our website via the following links www wiking com dop luma...

Страница 22: ...able as possible and that is in line with the current environmental protection reprocessing recycling and disposal technology Useful efficiency at nominal heat output 81 Energy efficiency index 107 En...

Страница 23: ...ve the air control lever further to the left The temperature inside the stove is too low Put more wood in the stove and move the regulating lever further to the left Smoke enters the room when I open...

Страница 24: ...anty service It is important that you record your retailers name address and telephone number on this section as he is responsible for any ajustment which may be required during the warranty period Mo...