Manufactured Specifically for Each Application 

 
 

Every WIKA 

WMI

 Series Magnetic Level Indicator is designed and manufactured specifically for each Level 

Application.  Careful attention is given to process conditions, most importantly the Specific Gravity, Temperature 
and Pressure of the liquid to be measured. 

 

Extreme caution should be taken before applying a Gauge to a differing application, or should the original process 
conditions differ from those for which the Gauge has been designed.  Please consult the factory to make sure that 
the instrument can withstand and/or operate under these modified requirements. 

 

 

 

Shipment 

 

Special care is taken to ensure that every WIKA 

WMI

 Series Magnetic Level Indicator arrives complete and ready 

for installation.  Carefully inspect every package to ensure that it has not been damaged during shipping.  If damage 
is observed, immediately contact the shipping company that delivered the instrument and file a claim. 

 
 

Unpacking/Inspection 

 

Upon opening of the shipping container, carefully inspect each instrument to ensure that it has arrived complete 
and ready for installation.  Note that the process conditions are listed on the tag mounted at the base of the 
indicator assembly.  Make sure that these process conditions match the application for which this gauge is designed. 
 
Should there be damage to The 

WMI

 Series Magnetic Level Indicator, try to take digital pictures if possible.  Take 

note of the serial number of the instrument and contact WIKA Instrument Corporation so that we can take action 
to repair/replace this instrument.   

 
 

Storage 

 

Although these level instruments are manufactured for installations that are not necessarily sheltered from the 
environment, care should be taken to ensure that no damage occurs from the time these instruments are delivered 
to the time that they are installed or while in storage.  Packaging is designed to withstand shipping and lifting.  It will 
not withstand continual moisture from rain or rising water.  Instruments should be stored in a dry place under 
shelter, if possible, in temperatures not below 32 or above 150 Degrees Fahrenheit.  Objects should not be stacked 
on top of these packaged instruments.   

 
 
 
 
 

Содержание WMI Series

Страница 1: ...NSTALLATION AND OPERATION MANUAL WIKA WMI Series Magnetic Level Indicator Please retain for future usage Contact WIKA Instrument Corporation 950 Hall Court Deer Park TX 77536 www wika com 1 800 570 4454 ...

Страница 2: ...e measured As the liquid level increases and decreases in the chamber the float rises and falls with the liquid level This float contains a magnet assembly The force or flux of the magnet assembly contained in the float affects a visual indicator mounted outside of and isolated from the float chamber This same magnetic force can also affect optional switches or transmitters mounted outside of the ...

Страница 3: ...he shipping container carefully inspect each instrument to ensure that it has arrived complete and ready for installation Note that the process conditions are listed on the tag mounted at the base of the indicator assembly Make sure that these process conditions match the application for which this gauge is designed Should there be damage to The WMI Series Magnetic Level Indicator try to take digi...

Страница 4: ...on valves between the Level Gauge and the process tank This will allow for gradual pressurization of the Level Gauge chamber as well as facilitate any future maintenance necessary The gauge should be mounted level to ensure proper float travel without friction The WIKA WMI Series Magnetic Level Indicator arrives complete with the float installed No further assembly should be required Included with...

Страница 5: ...ction entitled Maintenance to learn the proper procedure for removing this instrument from service Functional Test The best way to provide a functional test for this instrument is to raise and lower the level of the material in the tank and therefore the gauge Many times this is not possible If this is the case utilize one of the following options 1 Make sure the chamber is isolated from process c...

Страница 6: ...the gauge Caution Take care to not allow the float to drop on the floor This can cause damage to the float and or the magnet assembly 5 Clean out chamber with a brush and wash with water if compatible Make sure there are no remaining solid particles Look for items or debris that will inhibit the movement of the float Further inspect the gauge chamber to ensure that it is free from unexpected corro...

Страница 7: ...f its use Seller makes no warranties as to the equipment manufactured by it which extend beyond the description of such equipment on the face hereof WIKA Instruments Corporation s obligation to correct defects in such equipment by repair or replacement in accordance with the foregoing provisions is in lieu of any other warranties expressed or implied as to such equipment WIKA Instruments Corporati...

Отзывы: