12
WIKA operating instructions, model MG-1
11609681.03 08/2019 EN/DE/FR/ES
EN
Cable outlet, shielded
2-wire
3-wire
U
B
brown
brown
0V
blue
blue
S
+
-
black
Wire cross-section 3 x 0.14 mm²
Cable diameter 4.3 mm
Cable length 2 m
3.9
Cleanliness specifications
Level of cleanliness
Measuring range < 30 bar [435 psi]
Measuring range > 30 bar [435 psi]
Breathing gas
Oil and grease free
Oil and grease free
Residual hydrocarbons
< 1,000 mg/m²
< 1,000 mg/m²
Medical standard
per ISO 15001
per ISO 15001
Residual hydrocarbons
< 550 mg/m²
< 220 mg/m²
Particle size
not applicable
on request
Industrial standard
Oil and grease free for oxygen per ASTM G93
level D/E
Oil and grease free for oxygen per ASTM G93
level D/E
Residual hydrocarbons
< 550 mg/m²
< 220 mg/m²
High industrial standard
Oil and grease free for oxygen per
ASTM G93 level C
Oil and grease free for oxygen per ASTM G93
level C
Residual hydrocarbons
< 66 mg/m²
< 66 mg/m²
3.10 Packaging
Level of cleanliness
Type of packaging
Breathing gas
Protection cap on the process connection
Medical standard
Protection cap on the process connection, instrument sealed in a plastic bag
Option: Protection cap on the process connection, instrument sealed in two
plastic bags
Industrial standard
High industrial standard
3. Specifications
Содержание MG-1
Страница 40: ...40 WIKA Betriebsanleitung Typ MG 1 DE 11609681 03 08 2019 EN DE FR ES Anlage BAM Prüfbericht für Typ MG 1 ...
Страница 41: ...41 WIKA Betriebsanleitung Typ MG 1 DE 11609681 03 08 2019 EN DE FR ES Anlage BAM Prüfbericht für Typ MG 1 ...
Страница 42: ...42 WIKA Betriebsanleitung Typ MG 1 DE 11609681 03 08 2019 EN DE FR ES Anlage BAM Prüfbericht für Typ MG 1 ...
Страница 83: ...83 WIKA manual de instrucciones modelo MG 1 11609681 03 08 2019 EN DE FR ES ES ...