Operating Instructions Horizontal Magnetic Float Switch - HLS
17
5.3.3 RC modules for switch protection
Depending on the operating voltage, RC modules should only be used in
accordance with the table below.
Other RC modules that those listed here will result in the destruction of
the Reed switch.
For reed contacts from 10 - 40VA
Capacity
Resistance
Voltage
Type
0.33 µF
100 Ohm
24 V ~
A 3/24
0.33 µF
220 Ohm
48 V ~
A 3/48
0.33 µF
470 Ohm
115 V ~
A 3/115
0.33 µF
1500 Ohm
230 V ~
A 3/230
For reed contacts from 40 - 100VA
Capacity
Resistance
Voltage
Type
0.33 µF
47 Ohm
24 V ~
B 3/24
0.33 µF
100 Ohm
48 V ~
B 3/48
0.33 µF
470 Ohm
115 V ~
B 3/115
0.33 µF
820 Ohm
230 V ~
B 3/230