WIKA operating instructions, models F4801, F4802, F4818
ADPR1X914110.01 08/2020 EN/DE
EN
5. Commissioning, operation
5. Commissioning, operation
5.1 Mounting preparation
■
Single point load cells are sensitive measuring instruments and must be handled with
appropriate care.
■
When commissioning the single point load cell, ensure that the mounting surface is
level, clean and free of grease.
5.2 Mounting instructions
CAUTION!
Damage to the instrument through improper commissioning
■
The force introduction is carried out via a platform mounted on the
single point load cell. The load can be positioned anywhere on this
platform. Pay attention to the platform size, see chapter 9 "Specifica-
tions".
■
Avoid too high torsional and transverse forces. Torsional torques and
transverse loads or lateral forces cause measuring errors and may
permanently damage the single point load cell.
■
During installation of the single point load cell, the output signal (force
value) must always be monitored to avoid mechanical overload.
■
The single point load cell may only be loaded in the intended load
direction, see chapter 3 "Product label".
■
Incorrect loads in the wrong load direction can permanently damage
the single point load cell.
■
An overload must be excluded at all times.
■
When assembling, ensure that the single point load cell has sufficient
spring displacement , see chapter 5.3 "Assembly". If necessary, use a
spacer part.
■
The max. torque for fastening the single point load cell must be
observed, see chapter 9 "Specifications".
■
If necessary, a limit stop must be used as overload protection when
installing the load cell.