22
WIKA operating instructions, models F2802, F2808
ADPR1X914114.01 07/2020 EN/DE
EN
9. Specifications
Model F2808
Rated force F
nom
N
5 / 10 / 20 / 50 / 100 / 200 / 250 / 300 / 500 /
1,000 / 2,000
Relative linearity error d
lin
±0.15 % F
nom
Relative creep, 30 min.
±0.1 % F
nom
Relative reversibility error v
±0.1 % F
nom
Relative span in unchanged mounting
position b
rg
±0.1 % F
nom
Relative deviation of zero signal d
S, 0
±2 % F
nom
Limit force F
L
150 % F
nom
Breaking force F
B
300 % F
nom
Material of the measuring body
Stainless steel
Rated temperature range B
T, nom
-10 … +60 °C
Service temperature range B
T, G
-20 … +80 °C
Input resistance R
e
380 ± 30 Ω
Output resistance R
a
380 ± 5 Ω
Insulation resistance R
is
≥ 5,000 MΩ/DC 100 V
Output signal (rated output) C
nom
5 N
1.5 ± 10 % mV/V
≥ 10 N
2.0 ± 10 % mV/V
Electrical connection
M3, M4
Cable Ø2 x 3,000 mm
M8
Cable Ø3 x 3,000 mm
Excitation voltage B
U, nom
DC 5 V (max. 10 V)
Ingress protection (per IEC/EN 60529)
IP66
Weight in kg
0.1