WEATHERPROOF AND INTRINSICALLY SAFE: SERIE DW03 

WEATHERPROOF AND INTRINSICALLY SAFE: SERIE DW05 

 

 

A

 

High pressure connection

 

B

 

Low pressure connection

 

C

 

Cable entry

 

Weight 2,2 kg (dimensions in mm) 

A

 

High pressure connection

 

B

 

Low pressure connection

 

C

 

Cable entry

 

Weight 8,2 kg (dimensions in mm) 

For surface mounting use two screws M6. 

For surface mounting use six screws M6. 

 

NOTE

: dimensions and weights are not binding unless released on certified drawings. 

 

CAUTION 

  Before installing, using or carrying out maintenance on the instrument it is necessary to

 read 

and

 understand 

the indications given in the 

attached Instruction Manual. 

  The instrument must only be installed and maintained by 

qualified personnel 

 

 INSTALLATION IS TO BE CARRIED OUT ONLY AFTER CHECKING THAT INSTRUMENT CHARACTERISTICS ARE CONSISTENT 

WITH PROCESS AND PLANT REQUIREMENTS. 

 The 

functional 

features

 of the instrument and its degree of protection are shown on the identification plate fixed to the case. 

 

CONTENTS:

 

1

 

GENERAL NOTES

 

2

 

OPERATING PRINCIPLE

 

3

 

MODEL CODE

 

4

 

IDENTIFICATION PLATE AND MARKINGS

 

5

 

SET POINT REGULATION

 

6

 

SET POIT CALIBRATION

 

7

 

MOUNTING AND CONNECTIONS

 

8

 

INSTRUMENT PLUMBING

 

9

 

SAFETY INTEGRITY LEVEL (SIL) INSTALLATION REQUIREMENTS

 

10

 

PUTTING INTO OPERATION

 

11

 

VISUAL INSPECTION

 

12

 

FUNCTIONAL VERIFICATION

 

13

 

STOPPING AND DISMOUNTING

 

14

 

DISPOSAL

 

15

 

TROUBLESHOOTING

 

 

SAFETY INSTRUCTIONS FOR USE IN HAZARDOUS ATMOSPHERES. 

 

RECOMMENDATIONS FOR PRESSURE SWITCH SAFE USE. 

 

 

RELATED DOCUMENT 

To authenticated document with certificate 

N° IECEx PRE 16.0074X

 