WIKA data sheet CT 15.51 ∙ 03/2019 

Page 12 of 15

The WIKA-Cal calibration software is used for generating 

calibration certificates or logger protocols for pressure 

measuring instruments and is available as a demo version for 

a cost-free download.

A template helps the user and guides him through the 

creation process of a document.

In order to switch from the demo version to a full version of 

the respective template, a USB key with the template has to 

be purchased.

The pre-installed demo version automatically changes to 

the selected full version when the USB key is inserted and 

is available as long as the USB key is connected to the 

computer.

 

Creation of calibration certificates for mechanical and 

electronic pressure measuring instruments

 

A calibration assistant guides you through the calibration

 

Automatic generation of the calibration steps

 

Generation of 3.1 certificates per DIN EN 10204

 

Creation of logger protocols

 

User-friendly interface

 

Languages: German, English, Italian and more due with 

software updates

For further information see data sheet CT 95.10

WIKA-Cal calibration software

Easy and fast creation of a high-quality calibration certificate

Calibration certificates can be created with the Cal-Template and logger protocols can be created with the Log-Template.

Cal Demo

Generation of calibration certificates limited to 2 measuring points, with 

automatic initiation of pressures via a pressure controller.

Calibration certificate

Kalibrierzeugnis

Certificate No.

00000122

Zeugnis-Nr.

Page

1 / 2

Seite

Demo laboratory
Demo street 123
12345 Demo city
Demo country

Tel.: 01234/56789
Fax: 01234/56789
E-Mail: [email protected]
www.demo.com

General

Allgemein

Device under test (DUT)

Kalibriergegenstand (KG)

Environmental conditions

Umgebungsbedingungen

Place of calibration

Ort der Kalibrierung

Measurement conditions

Messbedingungen

Calibration certificate

Kalibrierschein

Customer

Demo customer

Kunde

Demo street

DE-12345 Demo city

Customer order No.

Kundenbestellnummer

Order date

Bestelldatum

Date of calibration

01/02/2017

Datum der Kalibrierung

Operator

Demo User

Bearbeiter

Electrical gauge

Elektrisches Druckmessgerät

Model

D-10

Typ

Serial number

demo1234

Seriennummer

Scale range

(0 ... 10) bar g

Anzeigebereich

Accuracy

0.05 % FS

Genauigkeit

Resolution (scale division)

0.0001 bar

Auflösung (Skalenwert)

Measuring point No.

demo tag

Messstellen-Nr

Temperature

(20,0 ± 0,1) °C

Temperatur

Atmospheric pressure

(1013,0 ± 0,1) hPa

Atmosphärischer Luftdruck

Rel. humidity

(40 ± 1) %

Rel. Luftfeuchte

Demo place

g = (9.80946 ± 0.01) m/s²

Musterort

Working standard (WS) Pressure controller

Gebrauchsnormal (GN) Druckcontroller

Model

Demo CPC

Typ

Calibration mark

Demo 12345

Kalibrierzeichen

Scale range

(0 ... 10) bar g

Anzeigebereich

Accuracy

0.02 % FS

Genauigkeit

   

Calibration certificate

Kalibrierzeugnis

Certificate No.

00000122

Zeugnis-Nr.

Page

2 / 2

Seite

Demo laboratory
Demo street 123
12345 Demo city
Demo country

Tel.: 01234/56789
Fax: 01234/56789
E-Mail: [email protected]
www.demo.com

Measurement results

Messergebnisse

Statement of compliance

Konformitätsaussage

Reference value WS

Reading DUT

Referenzwert GN

Ablesung KG

bar

bar

0.00000

0.0000

0.0010

10.00000

10.0010

10.0020

Object keeps the specifications!

Der Kalibriergegenstand hält die Herstellerspezifikationen ein!

Cal Light

Generation of calibration certificates with no limitations on measuring 

points, without automatic initiation of pressures via a pressure 

controller.

Log Demo

Creation of data logger test reports, limited to 5 measured values.

Log

Creation of data logger test reports without limiting the measured 

values.

Содержание CPH7000

Страница 1: ...smitter via the electrical module and to measure or also simulate its output signal Functions The calibrator offers the possibility to set calibration routines quickly and easily but also to run preconfigured calibration routines and automatically save the measured values Over the WIKA Wireless interface the completed calibration processes can be transmitted to a PC This data can subsequently be e...

Страница 2: ...calibrator model CPH7000 Display Display Touchscreen colour display Display resolution up to 5 digits selectable Pressure units mbar bar psi Pa kPa hPa MPa mmHg cmHg inHg mmH2O mH2O inH2O 4 C inH2O 20 C inH2O 60 F inHg 0 C inHg 60 F kg cm kp cm lbf ft kN m atm Torr micron g l 20 C kg m 20 C as well as two user defined units Settings Applications Apps Measure calibrate logger switch test Measuring ...

Страница 3: ...y Measure 0 01 1 µA Supply 0 01 2 µA 8 Voltage Measuring input DC 0 30 V Measuring output DC 24 V Resolution 1 mV Accuracy 0 01 or reading 1 mV Barometric reference 1 9 Measuring range 850 1 100 mbar 12 3 16 psi Accuracy 1 mbar 1 Optional 5 The internal reference sensor is only available in combination with a pneumatic unit 6 It is defined by the total measurement uncertainty which is expressed wi...

Страница 4: ...obe diameter 3 mm 0 12 in Cable length 1 m 3 28 ft Connection to CPH7000 max 1 temperature probe 2 User defined RTD probe Input of the coefficients of R0 A B and C Ambient module 1 Measuring range Air humidity 0 100 r h Temperature 30 125 C 22 257 F Accuracy Air humidity 5 r h Temperature 0 2 K 0 36 F Connection to CPH7000 max 1 ambient module 2 WIKA Wireless 4 Frequency range 2 400 2 500 MHz HF o...

Страница 5: ... times 1 600 bar 1 1 times 6 000 bar 3 times 360 psi 2 times 360 psi 8 700 psi 1 5 times 8 700 psi 25 000 psi 1 3 times 25 000 psi 1 1 times 85 000 bar Process connection Selectable versions G B G B G female G B G male on G female G B flush with O ring of NBR G B flush with O ring of EPDM G 1 B flush with O ring of NBR G 1 B flush with O ring of EPDM NPT NPT NPT male on NPT female NPT female M16 x...

Страница 6: ...r 9 84 ft connection cable plug and play Ingress protection IP65 IP67 when connected Dimensions see technical drawing Weight approx 230 g 0 5 lbs 11 For oxygen versions the medium temperature must not exceed 60 C 140 F Approvals Logo Description Country EU declaration of conformity for CPH7000 EMC directive EN 61326 emission group 1 class B and interference immunity portable measuring equipment R ...

Страница 7: ... Uzstandard 12 Metrology measurement technology Uzbekistan 12 Optional Certificates Certificate Calibration Standard 3 1 calibration certificate per EN 10204 Option DKD DAkkS calibration certificate Recommended recalibration interval 1 year dependent on conditions of use Patents property rights Patents Design Registered under USD 786 719S Approvals and certificates see website ...

Страница 8: ...WIKA data sheet CT 15 51 03 2019 Page 8 of 15 Dimensions in mm in Reference pressure sensor model CPT7000 Digital process calibrator model CPH7000 ...

Страница 9: ...aximum and Minimum memory e g for leak testing Alarm function for safety testing For further information see the operating instruction Application icons app The home screen is very clearly subdivided into application oriented apps Measure Display of 3 different measurements Logger Simultaneous recording of up to 3 signals Info All instrument information available at a glance Remote WIKA Wireless r...

Страница 10: ...ftware Up to 100 calibrations can be stored Re calibrations possible PC software available Communication with WIKA Cal calibration software via WIKA Wireless Operating mode Calibrate Features Pressure display on the closing and opening of the switch Automatic calculation of the hysteresis Operating mode Switch test Switch test with external voltage supply Switch test with voltage supply DC 24 V of...

Страница 11: ...red value at the same time Automatic or manual data acquisition Direct display as graph or table Logger protocols are automatically saved Applications Logging of current voltage pressure and temperature The logger menu guides one step by step through the logger process The data sets incl date and time are automatically saved in the CPH7000 Before logging the data routines can be set directly on th...

Страница 12: ...nder test DUT Kalibriergegenstand KG Environmental conditions Umgebungsbedingungen Place of calibration Ort der Kalibrierung Measurement conditions Messbedingungen Calibration certificate Kalibrierschein Customer Demo customer Kunde Demo street DE 12345 Demo city Customer order No Kundenbestellnummer Order date Bestelldatum Date of calibration 01 02 2017 Datum der Kalibrierung Operator Demo User B...

Страница 13: ...e 7 Pressure connection set model Minimess 1620 incl test item hose length 1 m 3 28 ft 8 Dirt trap set Standard Consisting of Dirt trap Sealing set Hose Hose connection G via hose to G G NPT or NPT female L Dirt trap set with knurled nut Consisting of Dirt trap Knurled nut Sealing set Hose Hose connection G via hose to G G NPT or NPT female M Sealing set Consisting of 4 x G USIT seals 2 x G USIT s...

Страница 14: ...ers T Sensor connection cable for reference pressure sensor model CPT7000 length 1 m 3 28 ft S for reference pressure sensor model CPT7000 length 3 m 9 84 V Temperature probe Pt100 uncalibrated P Atmospheric module E Power supply unit N WIKA Wireless USB Stick B Ordering information for your request 1 Order code CPH A 70 2 Option ...

Страница 15: ...n certificate per DIN EN 10204 Options DKD DAkkS calibration certificate Service case with process calibrator and accessories completely equipped Process calibrator model CPH7000 Ordering information CPH7000 Version Pressure generation Unit Pressure type Measuring range Accuracy Type of certificate Barometer Barometer calibration Atmospheric module Atmospheric module calibration Temperature probe ...

Отзывы: