WIKA operating instructions, model CPH62I0
11221801.02 02/2011 GB/D/F/E
GB
3. Specifications
Specifications
CPT62I0 reference pressure sensor
Pressure connection
1)
G½ B; {flush diaphragm (G1 for 0.1 up to 1.6 bar) or various connection adapters
on request}
Material
■
Wetted parts
Stainless steel or Elgiloy®
, (> 25 bar with NBR seal)
flush diaphragm version: stainless steel {Hastelloy C4}; O-Ring: NBR
3)
{FKM/FPM
or EPDM}
■
Internal transmission fluid
Synthetic oil, (only for pressure ranges up to 16 bar or flush diaphragm)
{Halocarbon oil for oxygen applications}; {Listed by FDA for food industry}
One year stability
0.2 % of span at reference conditions
Permissible
■
Medium temperature
1)
°C
-20 ... +50 (T4)
■
Ambient temperature
°C
-20 ... +50 (T4)
■
Storage temperature
°C
-40 ... +80
Protection class
IP 67 (Sensor) / IP 54 (Plug)
Compensated range
°C
0 ... 70
Temperature coefficients
■
Mean TC of zero signal
0.2 % / 10 K (< 0.4 for pressure ranges < 250 mbar)
■
Mean TC of span
0.2 % / 10 K
Supply circiut
■
Max. voltage
DC V
Ui = 10,4
■
Max. strength of current
mA
Ii
= 93
■
Max. power
mW
Pi = 500
■
Max. effective internal capacitance
nF
Ci = 600
■
Max. effective internal inductance
Li negligible
CE conformity
■
Pressure equipment directive
97/23/EC
■
EMC directive
2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (portable
equipment)
■
ATEX directive
94/9/EC, Category 2G, Ignition protection type Ex ib IIC T4
Connection to CPH62I0
via 1 m cable (plug & play); on request: up to 5 m
Weight
g
approx. 220
1) In an oxygen version, a flush diaphragm model is not available. In an oxygen version model CPT62I0 is only available in gauge pressure ranges ≥ 0.25
bar with media temperatures between -10 … +50 °C and using stainless steel or Elgiloy® wetted parts.
2)
For the intrinsically safe version, the use of the interface and analogue output is not permitted within an explosive atmosphere.
3) O-ring made of FKM/FPM or EPDM for flush diaphragm with integrated cooling element.
{}
Items in curved brackets are optional extras for additional price.
For further specifications see
WIKA data sheet CT 11.02 and the order documentation.
WARNING!
For further important safety instructions for the operation in hazardous
areas see chapter “2.3 Additional safety instructions for instruments
with ATEX approval”.
Содержание CPH62I0-S1
Страница 44: ...44 WIKA operating instructions model CPH62I0 11221801 02 02 2011 GB D F E GB...
Страница 85: ...85 WIKA Betriebsanleitung Typ CPH62I0 D 11221801 02 02 2011 GB D F E...
Страница 86: ...86 WIKA Betriebsanleitung Typ CPH62I0 D 11221801 02 02 2011 GB D F E...
Страница 120: ...120 WIKA mode d emploi type CPH62I0 F 11221801 02 02 2011 GB D F E Annexe 1 D claration de conformit CE type CPH62I0...
Страница 121: ...121 WIKA mode d emploi type CPH62I0 F 11221801 02 02 2011 GB D F E Annexe 2 D claration de conformit CE type CPT62I0...
Страница 122: ...122 WIKA mode d emploi type CPH62I0 F 11221801 02 02 2011 GB D F E...