WIKA CPB 5000 DP Скачать руководство пользователя страница 7

 Differential Pressure Balance / Differenzdruck-Kolbenmanometer 

 

 CPB 5000 DP

 

 
 

WIKA Operating Instructions Differential Pressure Balance Version 1.0 

7

 

4. Adressen / Adresses 

.

 

 

North 

America 

   

Africa/Middle East 

 

 

 

Canada 

WIKA Instruments Ltd. 
Head Office 
Edmonton, Alberta, T6N 1C8 
Phone: (+1) 780-463 70 35 
Fax: (+1) 780-462 00 17 
E-mail: [email protected] 
www.wika.ca 

 

Iran 

WIKA Instrumentation Pars (KFZ) 
Ltd. 
Anahita Tower, Tehran 
Phone: (+98-21) 8878 3514-17 
Fax: (+98-21) 8887 8593 
E-mail: [email protected] 
www.wika.ir 

 

Kazakhstan 

TOO WIKA Kazakhstan 
050050 Almaty 
Phone: (+7) 32 72 33 08 48 
Fax: (+7) 32 72 78 99 05 
E-mail: 
[email protected] 

 

WIKA Instruments Canada Ltd. 
Oakville, Ontario, L6H-6Z8 
Phone: (+1) 905-337 16 11 
Fax: (+1) 905-337 27 16 
E-mail: [email protected] 
www.wika.ca 

 

South Africa 

WIKA Instruments (Pty.) Ltd. 
Gardenview, Johannesburg 2047 
Phone: (+27) 11-621 00 00 
Fax: (+27) 11-621 00 59 
E-mail: [email protected] 
www.wika.co.za 

 

Korea 

WIKA Korea Ltd. 
Seoul 153-023 
Phone: (+82) 2 - 8 69 05 05 
Fax: (+82) 2 - 8 69 05 25 
E-mail: [email protected] 

 

Mexico 

Instrumentos WIKA Mexico S.A. 
de C.V. 
01219 Mexico D.F. 
Phone: (+52) 555 020 53 00 
Fax: (+52) 555 020 53 01 
E-Mail [email protected] 
www.wika.com.mx 

 

United Arab Emirates 

WIKA Middle East FZE 
Jebel Ali, Dubai 
Phone: (+971) 4 - 883 90 90 
Fax: (+971) 4 - 883 91 98 
E-mail: [email protected] 

 

Malaysia 

WIKA Instrumentation (M) Sdn. 
Bhd. 
Selangor Darul Ehsan 
Phone: (+60) 3 - 56 36 88 58 
Fax: (+60) 3 - 56 36 90 72 
E-mail: [email protected] 
www.wika.com.my 

 

USA 

WIKA Instrument Corporation 
Lawrenceville, GA 30043 
Phone: (+1) 770-513 82 00 
Fax: (+1) 770-338 51 18 
E-mail: [email protected] 
www.wika.com 

 

Asia 

.

 

 
China 

WIKA International Trading 
(Shanghai) Co., Ltd. 
200001 Shanghai 
Phone: (+86) 21 - 53 85 25 73 
Fax: (+86) 21 - 53 85 25 75 
E-mail: [email protected] 

 

Singapore 

WIKA Instrumentation Pte. Ltd. 
569625 Singapore 
Phone: (+65) 68 44 55 06 
Fax: (+65) 68 44 55 07 
E-mail: [email protected] 
www.wika.com.sg 

 

South America  

 

 

 

Argentina 

WIKA Argentina S.A. 
Buenos Aires 
Phone: (+54-11) 4730 18 00 
Fax: (+54-11) 4761 00 50 
E-mail: [email protected] 
www.wika.com.ar 

 

WIKA Instrumentation 
(Suzhou) Co., Ltd. 
215011 Suzhou 
Phone: (+86) 512 - 68 25 98 41 
Fax: (+86) 512 - 68 25 44 62 
E-mail: [email protected] 

 

Taiwan 

WIKA Instrumentation Taiwan Ltd. 
Pinjen, Taoyuan 
Phone: (+886) 034 20 60 52 
Fax: (+886) 034 90 00 80 
E-mail: [email protected] 
www.wika.com.tw 

 

Brazil 

WIKA do Brasil Ind. e Com. Ltda. 
CEP 18560-000 Iperó - SP 
Phone: (+55) 15-3266 16 55 
Fax: (+55) 15-3266 16 50 
E-mail: [email protected] 
www.wika.com.br 

 

India 

WIKA Instruments India Pvt. Ltd. 
Village Kesnand, Wagholi 
Pune - 412 207 
Phone: (+91) 20 - 27 05 29 01 
Fax: (+91) 20 - 27 05 19 25 
E-mail: [email protected] 
www.wika.co.in 

 

Australia 

.

 

 
Australia 

WIKA Australia Pty. Ltd. 
Rydalmere, NSW 2116 
Phone: (+61) 2 - 88 45 52 22 
Fax: (+61) 2 - 96 84 47 67 
E-mail: [email protected] 
www.wika.com.au 

 

 Japan 

WIKA Japan K. K. 
Tokyo 105-0023 
Phone: (+81) 3-54 39 66 73 
Fax: (+81) 3-54 39 66 74 
E-mail: [email protected] 

 

WIKA Australia Pty. Ltd. 
Burwood East, VIC 3151 
Phone: (+61) 3 - 88 47 20 00 
Fax: (+61) 3 - 98 02 95 59 
E-mail: [email protected] 
www.wika.com.au 

 

 

Содержание CPB 5000 DP

Страница 1: ...ebsanleitung CPB 5000 DP Addition to the operating instructions of the CPB 5000 Erg nzung zur Betriebsanleitung CPB 5000 Differential Pressure Balance GB Differential Pressure Balance CPB 5000 DP Diff...

Страница 2: ...Balance Version 1 0 2 Information This symbol provides you with information notes and tips Warning This symbol warns you against actions that can cause injury to people or damage to the instrument Ope...

Страница 3: ...to generate the line pressure The second one supplys the differential pressure including line pressure Following the description for the use of the instrument 3 Working principle Piston 2 Inlet Outlet...

Страница 4: ...spindle pump Now both systems should be in floating position If both systems float and spin the device under test is applied to a zero pressure Note but each port has an additional line pressure The s...

Страница 5: ...erell dient ein Messsystem zur Erzeugung des statischen Druckes Mit dem zweiten ConTect System erfolgt die Beaufschlagung des Pr flings mit dem Differenzdruck inkl statischen Vordruck Die Vorgehenswei...

Страница 6: ...liegt am Pr fling ein Differenz Nulldruck 0 bar an Die Sinkgeschwindigkeiten sollten vergleichbar sein Gegebenenfalls die Auflagen am statischen Kolben mit Feinmassen anpassen 3 2 Einstellen des Diff...

Страница 7: ...E mail info wika com my www wika com my USA WIKA Instrument Corporation Lawrenceville GA 30043 Phone 1 770 513 82 00 Fax 1 770 338 51 18 E mail info wika com www wika com Asia China WIKA Internationa...

Страница 8: ...16 E mail info wika donetsk ua Bulgaria WIKA Bulgaria EOOD 1309 Sofia Phone 359 2 82138 10 Fax 359 2 82138 13 E Mail t antonov wika bg Russia ZAO WIKA MERA 127015 Moskau Phone 7 495 786 21 25 Fax 7 4...

Отзывы: