![WIKA A-RB-1 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/wika/a-rb-1/a-rb-1_operating-instructions-manual_980436006.webp)
6
2.2.3 MIN mode (minimum memory) 'h'
The lowest value indicated since last hitting of the RESET key is
memorised and will be displayed in this mode. Measurement continues
in the background, meaning that the memories of MIN and MAX as well
as the alarm contacts continue to operate. MIN discontinues upon
further hitting of the MODE key. Hitting of the RESET key erases the
memory (see 2.7).
2.2.4 MAX mode (maximum memory) 'h'
The highest value indicated since last hitting of the RESET key is
memorised and will be displayed in this mode. Measurement continues
in the background, meaning, that the memories of MIN and MAX as well
as the alarm contacts continue to operate. MAX discontinues upon
further hitting of the MODE key. Hitting of the RESET key erases the
memory (see 2.7).
2.3 Set key descending value (
) 'B'
Selects the next lower value or individual parameter during program-
ming.
2.4 Set key ascending value (
) 'C'
Selects the next higher value or individual parameter during program-
ming.
2.5 Programming key PROG 'F'
Hitting of this key actuates the programming mode, at which all
operative parameters can be set and verified.
2.5.1 Programming the indication (see also appendix A)
All programming is made in consecutive order by initially holding the
PROG key pressed for approx. 5 seconds, until the message SCL (for
scaling) appears instead of PRO for programming.
Содержание A-RB-1
Страница 1: ...Operating Instructions Digital Indicator Model A RB 1 ...
Страница 34: ...34 89 5 47 5 95 7 173 5 Appendix C Dimensions Dimensions in mm ...
Страница 35: ...35 8 9 42 3 45 0 6 92 0 8 Panel cutout in mm Dimensions in mm ...
Страница 36: ...36 A B C D E F G H I d e h Appendix D Layout of front and back panel ...
Страница 38: ...38 For your notes ...
Страница 39: ...39 For your notes ...