Annex
© 2010 Wieland Electric GmbH | BA000256 | 12/2012 (Rev. I)
63
9
Annex
Anti-Manipulation Measures
Manipulation
... during operation
(power not switched
off)
... with power off
System response
System response when
power connected
Action required
Rotary switch
moved
All outputs shut down
immediately
System goes into
“System error”
condition
Red
FLT
LED on affected
module flashes
Green
PWR
LED flashes
All other
FLT
LEDs
continuous red
Message via field bus
coupler module
System outputs cannot
be switched on
Red
FLT
LED on master
module flashes
All other
FLT
LEDs
continuous red
Return switch to original
position (setting aid if
power remains on:
flashing
PWR
LED
switches to continuous
green)
Restart system by
switching power off and
on again
Change to
control circuit
configuration
(inputs
settings on
S1
,
S2
,
S3
)
Outputs of system/
system group shut
down at next cycle
Red
FLT
LED on affected
module flashes
Message via field bus
coupler module
System/system group
outputs cannot be
switched on
Red
FLT
LED on master
module flashes
All other
FLT
LEDs
continuous red
Restore old configura-
tions on
S1
,
S2
,
S3.
Restart system by
switching power off and
on again
Deliberate
acceptance of
an incorrect
configuration
The configurations are
saved internally in non-
volatile form and can be
read out by the
manufacturer if required
User reads out last
(correct) configuration
CRC via bus coupler
module
Cyclical visual check of
configuration
The leadable cover
SA-COVER
is available as an accessory for the safe
samos
modules. It
prevents the rotary switches from changing their setting after system start-up.
Error Codes of
FLT
Error LED
Blink code
Cause of error
Static
Secondary error on modules that have not discovered the error themselves
2x
Error in module configurations on
S1
,
S2
,
S3
, other module configuration
3x
Rotary switch altered during operation
4x
Module location list comparison when power switched on has detected a
difference (including alteration of rotary switch position before or during
power off)
5x
Voltage supply internal and external
6x
Self-monitoring, internal error, etc. (e.g. enter button pressed longer than 5 s)
Error codes FLT