Configuring a new RAID
The process for setting up a RAID on the RT5E is nearly the same as on the RT5. The few differences
are listed below. Note: If you purchased the RT5E with drives preinstalled and preconfigured, you can
skip this section.
To access over 2TB of storage with RT5E, a couple of settings will need to be changed.
1. When setting up a RAID, you will be prompted to set up a RAID over 2TB or below 2TB. Select the
option that will allow over 2TB.
2. Under ‘Modify Volume Set Attribute,’ change the IDE Host Channel to Channel 1.
3. Under ‘Modify Volume Set Attribute,’ change Tagged Queuing to Disabled.
(Refer to RT5 Full User Manual, section 5.5.3.3 for more information)
Main Menu >
Quick Volume/ Raid Setup
IDE Host Channel > Channel 1
Raid Set Functions
Volume Set Functions >
Modify Volume Set Attribute
Physical Drive Functions
Raid System Functions
Tagged Queuing > Disabled
View System Events
Clear Event Buffer
Hardware Monitor
System Information