f) Press [
BACK
] (see B) to return to [
P ROGRAM OPTIONS
]. An exclamation point (!)
will appear in the mode window next to [
FBC
] to indicate an adjustment to the Feedback
setting.
6. A manual adjustment to Audibility Extender can be made in the Program Options mode.
a ) P ress [
= =›
] in the [
P ROGRAM OPTIONS
]
mode window (see B) twice.
b) Press [
FBC
] in the mode window.
c) Press [
MA
] in the mode window.
d) [
MANUAL ADJUST
] will be displayed. The
default setting is [
0
].
e) Press the [
D OWN ARROW
] to lo wer the
max gain in one dB steps to a maximum of
15 dB.
f) Press [
BACK
] (see B) twice to return to the Program Options mode.
Note: If Feedback Cancellation has been turned off in any other listening programs, the
manual adjustment parameter can also be lowered for that program.
7. The Audibility Extender
Start Frequency
can be adjusted.
a) P ress [
= =›
] in the [
P RO G R A M
OPTIONS
] mode window (see B) twice.
b) Press [
AE
] in the mode window.
c) [
AUDIBILITY EXTENDER
] will be dis-
played. The default Start Frequency will be
displayed.
d) P ress the [
UP ARROW
] or [
D OW N
ARROW
] to adjust the Start frequency.
e) Press [
BACK
] (see B) to return to [
PROGRAM OPTIONS
]. An exclamation point will appear
in the mode window next to [
AE
] to indicate an adjustment to the Start Frequency.
Note: Changing overall Audibility Extender (AE) gain is an option
only
when programming
with Compass. AE gain
cannot
be adjusted on the iP5 programmer.
Turn Off iP5
Press [
ON R
] AND [
ON L
] simultaneously.
Note: If the iP5 is inactive for more than 5 minutes it will shut off automatically.
Binaural Listening Function
To provide binaural listening during fitting connect both hearing aids to the iP5. While one of
the hearing aids is active (i.e. Left) push [
ON
] for the other ear (i.e. [
ON R
]. The microphones
on both hearing aids will be active. However, program adjustments will only occur in the ear
selected for programming (i.e. Left). Push the [
ON
] button of the hearing aid you are program-
ming (i.e. [
ON L
] to deactivate the binaural mode.
5 . The Speech and Noise mode settings can be adjusted for each acoustic listening pro g ram, exc e p t
Audibility Extender, in the [
SPEECH – NOISE
] mode.
Note: Audibility Extender is displayed as [*
AE *
] in this screen to indicate that the listening
program has been selected but no change to the speech and noise setting can be made.
a) Press [
= =›
] in the [
PROGRAM OPTIONS
]
mode window (see B).
b) Press [
SN
] in the mode window.
c) The current setting for the Speech and Noise
mode will be displayed.
d) P ress the [
UP ARROW
] or [
D OWN ARROW
]
under the desired listening pro g ram to change
the Speech and Noise setting.
e) The order of the available options, when using the [
UP ARROW
], is:
• Speech Enhancer
[
SPNH
]
• Noise Reduction Off
[
OFF
]
• Classic Noise Reduction Minimum
[
W1
]
• Classic Noise Reduction
[
W2
]
• Classic Noise Reduction Enhanced
[
W3
]
• Noise Reduction Comfort
[
COMF
]
The order is reversed when scrolling with the [
DOWN ARROW
].
f) Press [
BACK
] (see B) to return to [
PROGRAM OPTIONS
]. An exclamation point (!) will
appear in the mode window next to [
SN
] to indicate an adjustment to the Speech and
Noise setting.
5. The Feedback Cancellation settings can be adjusted for each acoustic listening program,
except Audibility Extender, in the [
FEEDBACK CANCELLING
] mode.
Note: Audibility Extender is displayed as [*
AE *
] in this screen to indicate that the listening
program has been selected but no change to the feedback cancelling setting can be made.
a) Press [
= =›
] in the [
PROGRAM OPTIONS
]
mode window (see B) twice.
b) Press [
FBC
] in the mode window.
c ) The current setting for the Fe e d b a c k
Cancelling mode will be displaye d .
d ) P ress the [
UP ARROW
] or [
D OWN ARROW
]
under the desired listening pro g ram to
change the Feedback Cancelling setting.
e) The order of the available options, when using the [
UP ARROW
], is:
• Super Gain
[
STD
]
• Super Gain Max
[
MAX
]
• Super Gain Music
[
MUS
]
• Off
[
OFF
]
The order is reversed when scrolling with the [
DOWN ARROW
].
11
10
B
B
B
B
IN_IP5_Manual8.qxd 11/28/06 1:12 PM Page 10