background image

 

 

 

Issued Date 

Revision Status 

Title 

Page No. 

24 / 44 

V2.2 

2009-2-20 

IDP2310UX 

(AL23PUX) 

V position 

0x87, 

nnn l “+” l “-“ l 

“r” l “R” l 

“?” 

Set H position 

Value / increment / decrement

Reset 

Query 

vertical position 

PIP window size   

Select 

0xa6, 

n l   

“r” l “R” l 

“?” 

Select PIP window size = 

PIP window size value 

Reset 

Query 

PIP window size selected 

“0”

small size 

“1”

large size 

PIP source select 

0xa7, 

n l   

“r” l “R” l 

“?” 

Select input main = 

Video source value 

Reset 

Query 

Main selected. 

“0”

CVBS 

“1”

S-video 

PIP Location 

0xa4, 

n l   

“r” l “R” l 

“?” 

Select location = 

PIP location value 

Reset 

Query 

Select ed PIP location 

“0”

left top 

“1”

right top 

“2”

right bottom 

“3”

left bottom 

PIP ON / OFF 

0xa5, 

n l   

“r” l “R” l 

“?” 

Select PIP ON /OFF = 

PIP ON / OFF value 

Reset 

Query 

Select ed PIP location 

“0”

PIP turned off 

“1”

PIP turned on 

 

Video brightness   

control 

(CVBS,S-video only) 

0x84, 

nn l “+” l “-“ l 

“r” l “R” l 

“?” 

Set video brightness = 

Value / increment / decrement

Reset 

Query 

video brightness 

Video contrast 

control 

(CVBS,S-video only) 

0x83, 

nn l “+” l “-“ l 

“r” l “R” l 

“?” 

Set video contrast = 

Value / increment / decrement

Reset 

Query 

video contrast 

Graphic mode   

sharpness 

(Analog, BNC only) 

0x89, 

nnn l “+” l “-“ l 

“r” l “R” l 

“?” 

Set graphic mode sharpness  

Value / increment / decrement

Reset 

Query 

Graphic mode sharpness 

 

Video sharpness 

(CVBS,S-video only) 

0x8a, 

nnn l “+” l “-“ l 

“r” l “R” l 

“?” 

Set video mode sharpness    =

Value / increment / decrement

Reset 

Query 

video mode sharpness   

Select OSD   

language 

0x95, 

n l   

“r” l “R” l 

Select language = 

English, Korea 

Reset 

“0”

English 

“1”

Korea 

 

Содержание IDP2310UX

Страница 1: ...drawings data information or other material whether accompanying it are the property of WIDE Corporation are disclosed by WIDE only in confidence and except as WIDE may otherwise permit in writing are to be used disclosed or copied only to the extent necessary for the evaluation thereof by recipient or higher tier contractor or subcontractor Information in this document is subject to change withou...

Страница 2: ...TIONS 14 1 2 1 Dimension and Weight Rack Mount 14 1 2 2 Mounting 17 1 2 3 Finishing 17 1 2 4 Screws Bolts 17 1 2 5 Components 17 1 2 6 Cooling 17 1 3 ENVIRONMENTAL SPECIFICATIONS 17 1 3 1 Temperature 17 1 3 2 Humidity 17 1 3 3 Vibration 17 1 3 4 Altitude 18 1 3 5 EMC 18 1 3 6 Safety 18 1 3 7 Certificate for ECDIS 18 1 3 8 Drip proof 18 1 4 OHTER SPECIFICATIONS 18 1 4 1 Reliability 18 1 4 2 Maintai...

Страница 3: ...Issued Date Revision Status Title Page No 3 44 V2 2 2009 2 20 IDP2310UX AL23PUX 3 3 1 Adjustment 28 3 3 2 COLOR ADJ 31 3 3 3 PIP Picture In Picture 34 3 3 4 SETUP MENU 37 ...

Страница 4: ...d fans in the monitor cabinet are provided for ventilation To prevent overheating these openings and fans should not be blocked or covered Also avoid using the monitor on a bed sofa rug or other soft surface doing so may block the ventilation openings and fans in the monitor cabinet If you put the monitor in the enclosed space be sure to provide adequate ventilation 2 Put your monitor in a locatio...

Страница 5: ...oduct to fall and could cause injuries Do not install this product by alone Get some help from others Otherwise it may cause the product to fall and could cause injuries Do not place a heat source or a humidifier under the installed product Otherwise it may cause a fire or could give an electric shock Do not install this product near a high voltage electric line any power source or the place where...

Страница 6: ...nditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This party responsible for product compliance Provided with this monitor is a detachable power supply cord with IEC320 style terminations It may be suitable for connection to any UL Listed personal computer with termination Befo...

Страница 7: ...olors 8 bit per pixel Each pixel is divided into Red Green and Blue sub pixels which are arranged in vertical stripes and each sub pixel is controlled in 256 grey levels KEY FEATURES Color display 23 1 TFT LCD Monitor Full 1600 x 1200 resolution Two Analog BNC and D sub input single DVI input CVBS and S Video RS 422 RS 485 and RS 232 Communication Versatile mechanical version Rack mount Desktop Ty...

Страница 8: ...les 1 1 1 4 Resolution 1600 H x 1200 V pixels Pixel arrangement RGB Red dot Green dot Blue dot Vertical Stripe Pixel pitch 0 294 W x 0 294 H mm 1 1 1 5 Display mode Normally Black 1 1 2 Optical Characteristics 1 1 2 1 Protective Filter Glass Clear tempered glass Anti Reflective Film and Anti Static Treatment 1 1 2 2 Luminance Brightness 250 cd m max typical on LCD 240 cd m max typical on Protectiv...

Страница 9: ...XGA digital 1600 x 1200 75 60 0 Specified support resolutions Resolution H Frequency kHz polarity V Frequency Hz polarity 1600x1200 digital 75 60 1600x1200 analog 93 75 75 87 5 70 81 25 65 75 60 1280x1024 91 146 85 79 976 75 63 981 60 1024x768 68 667 85 60 023 75 56 476 70 48 363 60 800x600 53 674 85 46 875 75 48 1 72 37 879 60 35 1 56 640x480 43 269 85 37 5 75 37 7 72 31 469 60 720x400 31 469 70 ...

Страница 10: ...5 LED Indicator Fault information in available by LED indicators Normal Green indicator Soft Power Off Amber indicator No signal Amber Blinking every 1 second indicator System Fault Red indicator 1 1 6 Power Supply Specification 1 1 6 1 Voltage range Standard 100 264Vac 47 63Hz 1 0A at 230Vac 1 1 6 2 Power consumption Normal Max 100 Light output IDP2310UX 80 W 90W 1 1 6 3 Power variation protectio...

Страница 11: ...munication 1 1 8 Connection PIN Assignment Power Input output Analog Input BNC Analog Input D Sub 90 264Vac 47 63Hz with double pole neutral fusing 250V F3 15AL Disconnect power before changing fuse Chain thru power output to limit to one level totally R Analog Red Signal Input 0 7 Vpp 75 ohm G Analog Green Signal Input 0 7 Vpp 75 ohm B Analog Blue Signal Input 0 7 Vpp 75 ohm HS Horizontal Sync Si...

Страница 12: ...5 TMDS Data 4 6 DDC Clock 7 DDC Data 8 No Connection 9 TMDS Data 1 10 TMDS Data 1 11 TMDS Data1 3 Shield 12 TMDS Data 3 13 TMDS Data 3 14 5V power 15 Ground Return for 5V 16 Hot Plug Detection 17 TMDS Data 0 18 TMDS Data 0 19 TMDS Data 0 5 Shield 20 TMDS Data 5 21 TMDS Data 5 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 C5 No Connection Connection Type 4 pin DIN Jack 1 GND 2 LUMA 3 CROMA 4 ...

Страница 13: ...connection 2 RxD for RS 232 3 TxD for RS 232 4 TxIN_B for RS 485 5 RxIN_B for RS 485 6 No connection 7 Ground 8 TxIN_A for RS 485 9 RxIN_A for RS 485 Remote out male 1 No connection 2 No connection 3 No connection 4 TxOUT_B for RS 485 5 RxOUT_B for RS 485 6 No connection 7 Ground 8 TxOUT_A for RS 485 9 RxOUT_A for RS 485 ...

Страница 14: ... in the table below Monitor only Packing Height mm inch 534 21 02 780 30 71 Width mm inch 584 22 99 790 31 10 Depth mm inch 93 8 3 69 297 5 11 72 Weight kg lbs 15 5 34 2 20 5 45 2 The following figures show a Rack Mount version mechanical dimension IDP2310UX basically provides three input connectors and all connectors are located the bottom side of monitor IDP2310UX Front View unit mm ...

Страница 15: ...Issued Date Revision Status Title Page No 15 44 V2 2 2009 2 20 IDP2310UX AL23PUX IDP2310UX Bottom View IDP2310UX Rear View ...

Страница 16: ...Issued Date Revision Status Title Page No 16 44 V2 2 2009 2 20 IDP2310UX AL23PUX IDP2310UX Side View unit mm ...

Страница 17: ... temperature range components are used for cost maintainability and reproducibility purposes 1 2 6 Cooling The Unit does not need any forced air cooling 1 3 ENVIRONMENTAL SPECIFICATIONS The unit is designed to meet the following environmental standards 1 3 1 Temperature Operating 15 C 55 C 5 F 131 F Storage 40 C 70 C 40 F 158 F IEC60945 Note The unit may show limited performance in case of continu...

Страница 18: ... side is drip proof Test shall be done when the unit is mounted in a console Front bezel IP64 NOTE The unit is type approved according to EN60945 2002 4 4 equipment category b Protected from the weather formerly class B 1 4 OHTER SPECIFICATIONS 1 4 1 Reliability MTBF Mean Time Between Failures Standard calculated MTBF 40 986h MIL HDBK 217F Ship calculated MTBF 19 468h MIL HDBK 217F 1 4 2 Maintaina...

Страница 19: ...ose 1 4 3 Use of toxic materials Cold Cathode Fluorescent Lamp CCFL in the backlight assemblies contains a small amount of mercury The backlight assembly is placed inside of the monitor and is not exposed to user 1 4 4 Packing The unit shall be packaged for international transport by air freight in accordance with best practices for insuring arrival at customer site in an undamaged condition 1 4 5...

Страница 20: ...8 0x48 H 0x68 h 0x09 HT 0x29 0x49 I 0x69 i 0x0a LF 0x2a 0x4a J 0x6a j 0x0b VT 0x2b 0x4b K 0x6b k 0x0c FF 0x2c 0x4c L 0x6c l 0x0d CR 0x2d 0x4d M 0x6d m 0x0e SO 0x2e 0x4e N 0x6e n 0x0f SI 0x2f 0x4f O 0x6f o 0x10 DLE 0x30 0 0x50 P 0x70 p 0x11 DC1 0x31 1 0x51 Q 0x71 q 0x12 DC2 0x32 2 0x52 R 0x72 r 0x13 DC3 0x33 3 0x53 S 0x73 s 0x14 DC4 0x34 4 0x54 T 0x74 t 0x15 NAK 0x35 5 0x55 U 0x75 u 0x16 SYN 0x36 6...

Страница 21: ...ing the 0x07 Attention Code The display will respond to the Command with either an ACK if the command completed successfully or a NAK if the command failed Address ADDR This byte is used to specify a particular display to receive a command and to identify the display responding ACK or NAK to a command All displays will support the broadcast address The display will meet all functional requirements...

Страница 22: ...luminance If the data checksum is valid and the brightness was set the display will reply to this command with an ACK attention code The DATA field in the reply will indicate the resulting brightness control setting If an invalid checksum was received and the message was not Broadcast and RS485 the display will reply with an NAK attention code The DATA field in the reply will indicate the current ...

Страница 23: ...et the level of the green channel for the selected color temp Value increment decrement Reset Query Green level for selected color temperature bule level for selected Color temperature 0xb6 nn l l l r l R l Set the level of the Bule channel for the selected color temp Value increment decrement Reset Query Bule level for selected color temperature Clock frequency Analog bnc only 0x8b nnn l l l r l ...

Страница 24: ...bottom PIP ON OFF 0xa5 n l r l R l Select PIP ON OFF PIP ON OFF value Reset Query Select ed PIP location 0 PIP turned off 1 PIP turned on Video brightness control CVBS S video only 0x84 nn l l l r l R l Set video brightness Value increment decrement Reset Query video brightness Video contrast control CVBS S video only 0x83 nn l l l r l R l Set video contrast Value increment decrement Reset Query v...

Страница 25: ...e increment decrement Reset Query OSD Horizontal position Soft Power On Off 0xc8 0 l 1 l Soft power Off on Query 0 soft power off 1 soft power on Query information status 0xc9 read the status of information 0 serial number 1 s w ver 2 temperature value 3 input satus 4 communication 5 backlight value Query PCBA number 0xcb 1 Read PCBA number nnnn PCBA number Factory Recall 0xce Reset all parameters...

Страница 26: ... by 1 0x31 nn 2 byte ascii coded hex number e g parameter value of 0 x 1e is represented by 1 e l E 0x31 0x6el0x4e 3 User Controls 3 1 Operation POWER ON AND OFF Power ON To turn the display on press the soft power switch The LED indicator will turn green Power OFF To turn the display off press the soft power switch for 5 seconds The LED indicator will be turned Amber color DISPLAY DIMMING CONTROL...

Страница 27: ...Press and hold the MENU and SELECT for 5 second simultaneously 3 2 USER Control Access 1 Press the MENU button The OSD menu will show all the available functions you can adjust or control 2 You can move to the next icon by pressing and 3 Select options within icon menu by pressing SELECT button The select option will turn yellow 4 Use or button to decrease increase values 5 Move the selection left...

Страница 28: ...to 127 it is the darker it is and the closer to 127 it is the brighter it is When one of the submenu of Adjustment is selected the select button push to select it so that adjusts the values of the brightness When the menu button is pushed going back to the upper menu To adjust the brightness is to remap the input data to output data in terms of black and white level It is to change the range of da...

Страница 29: ...pth between black and white is expanded On the other way if it is min 0 input data 0 255 is mapped to 0 127 so the depth is reduced The contrast adjustment acts on the displayed image of all input data R G and B by the same level And it also controls the data to panel but it does not adjust the input i l The function is able the user to adjust horizontal position of image H Position is the submenu...

Страница 30: ... If the value of V position is increased or decreased by pressing and the V position shifts the upper or the lower The function is able the user to adjust sharpness for the display Closer to 0 Original Closer to 100 Sharpness is for making a clear image Its adjustment range is 0 to 100 When it is 100 the image is the most clear When it is closer to 0 the image is blurred This is not the absolute v...

Страница 31: ...he Clock is the menu for the setting of the number of pixels corresponding to the pixel rate of the applied analog input signal It represents the number of sampling clock during one period of horizontal sync signal The function is able the user to adjust phase of sampling clock Its range is 0 to 360 which is adjusted by 5 625 per one step and can be totally adjusted to 64 steps This is not represe...

Страница 32: ...cture for the Display Higher temperature cooler picture Lower temperature warmer picture User can select one of 9200K 6400K 5600K and User color temperature measured You can adjust color temperature via the User RGB The function is able the user to adjust Red Green and Blue offset for the display These set up the gain of black level of input video signal to ADC amp Analog to Digital Converter ...

Страница 33: ...er level adjust the white level But it also effects on dark level 3 3 2 3 BLACK LEVEL The function is able the user to adjust Red Green and Blue gain for the display These set up the offset of video signal of ADC amp When all black levels are on the points of OSD 50 the amount of color is the same each other But if the level is moved closed to OSD 100 the amount of color to adjust is more so the c...

Страница 34: ...ture This function is for displaying the video image window on the image from PC CVBS or S Video is possible to display on PIP window The image from PC over DVI BNC and D sub connector is unable to display on the window 3 3 3 1 PIP ON OFF This function is able the user to configure PIP window ON OFF PIP ON ...

Страница 35: ...Issued Date Revision Status Title Page No 35 44 V2 2 2009 2 20 IDP2310UX AL23PUX 3 3 3 2 PIP SIZE This function is able the user to configure PIP window size PIP Size Small PIP Size Large ...

Страница 36: ...evision Status Title Page No 36 44 V2 2 2009 2 20 IDP2310UX AL23PUX 3 3 3 3 PIP LOCATE The function is able the user to the configure PIP horizontal and vertical position Left Top Right Top Left Bottom Right Bottom ...

Страница 37: ...09 2 20 IDP2310UX AL23PUX 3 3 3 4 PIP SOURCE 3 3 4 SETUP MENU In this menu user can set up the setting values The function is able the user to configure PIP input source CVBS manual select composite video signal only SVIDEO manual select S Video signal only ...

Страница 38: ...2310UX AL23PUX 3 3 4 1 INPUT SELECT 3 3 4 2 COMMUNICATION The function is able the user to select one of Analog RGB D sub Digital RGB BNC CVBS and S Video Communication represents the communication setting between monitors or between the control system and the monitor ...

Страница 39: ...nication rate 1200 2400 4800 9600 57600 and 115200 baud rate that the system can support This assigns the monitor s number range Zero to fifteen in order to identify the monitors and it must be unique for distinguishing from each other And In the case of chaining several monitors thru communication port the ID of monitor to be connected with control system must by Zero ...

Страница 40: ...P This assigns the communication mode The monitor connecting with the control system is assigned the RS232 or RS422 and it connecting with other monitor is assigned to the RS485 So one of three must be chosen as input communication mode OSD Set Up is the submenu of Set Up which sets up the position of OSD and OSD Timeout ...

Страница 41: ...st the horizontal position of OSD This function is able to adjust the vertical position of OSD OSD Timeout is the submenu of OSD Set Up which controls the time to display the OSD menu 20 30 50 and 100 When the user don t touch anything the OSD menu is disappeared after 20 30 50 or 100 seconds which keeps display OSD This function is able to choose the OSD language one of English or Korean ...

Страница 42: ...009 2 20 IDP2310UX AL23PUX 3 3 4 4 Buzzer Set Up 3 3 4 4 1 On Off 3 3 4 4 2 Volume This function is available to the buzzer model only This function is buzzer on off and adjusts volume controls Buzzer On Off control The sound adjust the low middle and high ...

Страница 43: ...factory are stored in a factory settings storage area on main control board And the current settings are stored in a user settings storage area on main control board At administrator level the current settings are replaced by the factory settings The user settings disappear after changing by the factory settings This function describes the Serial Number S W version Temperature input source communi...

Страница 44: ...W ver describes the version of software installed on monitor 3 3 4 6 3 Temp Temp Status describes the current internal temperature status or the information of the warning level 65 the critical Value 80 and the safe level 64 See 1 1 6 4 3 3 4 6 4 Input A signal to display now on screen is described 3 3 4 6 5 Comm Comm represents a communication mode 3 3 4 6 6 Backlight Backlight represents the lig...

Отзывы: