Description

 

 
The NC96 MAT control unit has been designed for the control of pressure 
sensitive mats and safety edges in accordance with EN ISO 13856-1: 2013, 
EN ISO 13856-2: 2013, EN 60204-1: 2006 + A1: 2009, EN ISO 13849-1: 
2015. 
The operation of this module is based on the use of guided contact safety 
relays. 
 

             Safety precautions 

 
Pressure sensitive safety mats and edges perform a personal protective 
function. Incorrect installations or manipulations can cause serious personal 
injury. 
Pressure sensitive safety mats and safety edges must not be bypassed 
(shorting the contacts), moved, removed or otherwise rendered ineffective. 
The machine manufacturer or installer is responsible for correct and safe 
operation. 
The auxiliary exchange output NC 31/32 is optically insulated and provides a 
signal on the status of the device; therefore, it must not be used in any way 
as a safety output. 
The NC96 MAT module is not suitable for operation in the presence of 
ionizing and non-ionizing radiation (X-rays, microwaves, lasers, ultraviolet 
rays) (EN 60204-1: 2006, §4.4.7). 
 

Operation

 

 
The 

NC96 MAT

 safety control unit is able to control the status of pressure-

sensitive safety mats and edges: the output is activated automatically only if 
the two inputs are closed and if no operator is in the area covered by the 
mat. (edge). When the safety device is pressed, the control unit opens the 
safe outputs 13-14 and 23-24. 
Reset is possible only once the device is no longer pressed, in accordance 
with the requirements of EN ISO 13856-1: 2013 (Appendix A) and EN ISO 
13856-2: 2013 (Appendix A). 
The NC96 MAT can only be used with automatic start (reset); to configure 
the system with monitored manual start (reset) it is necessary to use the 

NC95

 control unit. 

 
The opening of even a single input connection determines a safety situation, 
placing the safe outputs in the open state and preventing their re-closing 
even after the contact has been re-closed.  
 
The system composed of NC96 MAT + carpet or pressure sensitive edge 
reaches the safety category 

3

 according to EN ISO 13849-1: 2015 only if 

(see connection drawing): 
- two relays are used to interrupt the load, each of which connected to an 
output of the control unit. 
- the relay contacts controlled by the control unit are inserted in the feedback 
ring. 
 
Safety is guaranteed by the use of guided contacts, redundancy and the 
interconnection scheme of the contacts. 
It is the responsibility of the user to choose suitable components for 
safety applications, such as guided contact relays. 

Installation 

 
The installation must be carried out only by authorized personnel. 
The NC96 MAT control unit must be installed in a suitable area of use 
(electrical panel, junction box, at least IP54). The control unit is installed by 
attaching it to a standard 35mm DIN omega rail. 
 

Electric connections 

 
Electrical connections must be made only by personnel authorized in 
accordance with EN 60204-1: 2006. 
All electrical inputs must be isolated from the main power supply or through a 
transformer with separate windings in accordance with EN IEC 61558-2-6 
with limited output voltage in the event of a defect, or by an equivalent 
removable mechanism. 
The power supply must be permanently connected using a cable with a 
maximum length of 10m; safety mat must be connected to the unit with 
cables with a maximum length of 30m. 
The relay outputs have a maximum current of 3A; the power supply 
connected to these outputs must be protected against overcurrent by 
devices suitable for the loads to be protected. 
All output contacts must have an adequate protection circuit for inductive and 
capacitive loads. 
If a standard power supply is used, all inductive and capacitive loads (e.g. 
relay contacts) connected to the power supply must be connected to an 
appropriate interference suppressor. 
 

Maintenance and checks 

 
The correct operation of the NC96 MAT control unit must be periodically 
checked by the operator and/or by the control circuit of the machine in which 
it is used periodically (at the beginning of each shift) by checking the 
following: 
- correct switching 
- secure attachment of components 
- correct fixing of the connections. 
 
The device monitoring function is performed at each intervention of the 
device itself. 
In case of failure or wear, the damaged system must be replaced. 
 

Warranty coverage disappears in the following circumstances: 

- if the instructions are not followed 
- non-compliance with safety regulations 
- installation and electrical connection not carried out by authorized 
personnel 
- failure to carry out functional checks. 
 

Setup

 

 
If the control unit does not seem to work when the supply voltage is applied 
(the green POWER LED does not light up), the unit must be returned sealed 
to the manufacturer. Check if the safety outputs switch (see LED table) by 
activating the inputs. 

 