![WIA weldmatic 350i CP139-2 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/wia/weldmatic-350i-cp139-2/weldmatic-350i-cp139-2_operators-manual_978625022.webp)
20
Operators Manual
Trusted by the best
3 Check that gun cable liner is not too
short and is fitted correctly. Refer
wirefeeder manual for fitting instructions.
Constant poor arc characteristics
Check that the:
1 Correct polarity has been selected for
work and weld cables
2 Shielding gas is correct for the
consumable wire in use
3 Welding circuit is making good electrical
connection. Ensure that the work clamp
is securely tightened onto the work piece
so that good electrical contact is achieved
4 All connections in the external welding
circuit are clean and tight. Problems may
show as hot spots
5 Work piece surface is not contaminated.
Water, oil, grease, galvanising, paint,
or oxide layers can severely disturb the
welding arc and result in a poor weld.
Porosity in weld caused by lack of
shielding gas
1 Check that the correct gas flow rate has
been set
2 Check for leaks in the gas hose. Replace
if leaking
3 Check for leaks in gun/cable assembly,
eg. fractured gas hose, broken or missing
‘O’ rings. Replace as required
4 Check the gun nozzle is free from spatter
and is firmly attached to the welding gun
to ensure that no air is being drawn into
the shielded area.
10 Service Information
Before removing the equipment
cover, ENSURE that the equipment
is disconnected from the mains
power supply. When the equipment
is energised LETHAL VOLTAGES are
present on the electrical components
enclosed.
The following information is intended
for use by qualified service personnel.
When the unit is energised LETHAL
VOLTAGES are present on the electrical
and electronic components. It is not
intended that persons without suitable
training and knowledge attempt
to perform service tasks on the
components of this welder.