39
RESETTING PUMP STEPS TO ZERO
At the same time press and hold down the PUMP STEP INCREMENT BUTTON
(5)
and the PUMP
STEP DECREMENT BUTTON
(4)
for approximately five seconds until counts return to zero. This will
only zero out the current direction selected.
NOTE: From the TOTALS screen you will not be able to zero out any counts for wheels or pump steps.
ERROR MESSAGES & TROUBLESHOOTING
WHEEL SENSOR CABLE ERROR
This error will only occur upon powering on the controller with the wheel sensor cable being unplugged or
not having a good connection. The STATUS LIGHT
(13)
will illuminate red and the message WHEEL CABLE
ERROR will display on line 4. To fix this power down the controller and ensure the wheel sensor cable is
properly connected. You must power cycle the controller in order to clear the error. (NOTE: cables should
never be connected/disconnected with the controller powered on)
DUAL WHEEL SENSOR ERROR
This error will only occur when a dual direction wheel sensor misses the leading axle in the A or B
direction. For example, if a trains lead axle passes over the wheel sensor B, but the controller does not get
a reading from wheel sensor A and gets a consecutive wheel sensor B reading, then the error “TRAIN WHL
A ERROR” displays on line 4. The STATUS LIGHT (13) will illuminate orange when this occurs. After 60
seconds of no train motion the display on line 4 will display “WHEEL A SENSE ERROR” or “WHEEL B SENSE