36
6)
Direction Button – This toggles the directional setting of the controller for Direction A and Direction B as
shown on the display. Upon powering up the controller Direction A is displayed as a default. Press
Direction Button once to go to Direction B settings, if using a dual direction sensor. Press Direction Button
a second time to go to the Total Wheel Counts and Total Pump Steps screen. Press Direction Button a third
time to return to Direction A. When Loco Skip is selcected (see 7) the direction button (6) is used to
alternate between Direction A and B.
7)
Loco Skip Button – Press this button once to enter the Loco Skip feature. This allows a delay in the pump
activation by “skipping” a set amount of wheels before beginning the standard pump activation process.
Once in the Loco Skip feature, use the Wheel Count increment (2) and Wheel Count decrement (3) buttons
to adjust the amount of wheels to skip. Use the Direction Button (6) to switch between A and B directions
for Loco Skip to be enabled. Press Loco Skip Button to exit the feature.
8)
Prime Button – Press button once to begin pump prime process. The pump will run continuously for up to
4 minutes, or until the Prime Button is pressed again. Line 4 of the display will show “PRIME IN PROCESS”.
9)
Test Button – Press button once to activate the pump for the set amount of steps according to the display
and direction selected.
10)
Wheel Sensor Light – When the track sensor detects a wheel is passing this red LED will illuminate. This
corresponds with the change of wheel sensor counts on the display. This light will remain illuminated
when there is a wheel present above the track sensor.
11)
Pump Sensor Light – When the pump sensor detects a gear tooth this red LED will illuminate. This
corresponds with the change of pump step counts on the display. The LED could potentially remain
illuminated depending on the position of the gear pump relative to the pump sensor.
12)
Pump Power Light – When the pump is activated this red LED illuminates
13)
Status Light – This is a multicolor LED light that is always on when the controller is powered up, even when
the display is in sleep mode. When the LED light is green there are no errors and the controller is
functioning as it should. When the LED light is red there is some type of error occurring that relates to the
battery being low, or there is a wheel sensor cable error. When the LED light is blinking orange there is a
pump sensor error 1 or 2. On the third pump sensor error the status light turns to solid red. These changes
in color helps indicate trouble shooting when an error occurs in conjunction with the display. A message
will appear on the display in conjunction with a red or orange Status Light error.
TURNING POWER ON/OFF
In order to access the control panel, open the main door of the cabinet by rotating the door handle
clockwise.
To turn the controller ON locate the toggle switch (1) on the left side of the control box and flip upwards.
The display and status light (13) will become illuminated.
Upon the controller powering up, there is a splash screen that displays for approximately four seconds.
This splash screen displays which configured version of the software the controller is currently set to use.
The two types are “WHITMORE RGD” and “WHITMORE TOR”. (See DISPLAY INFORMATION section below
for details)
To turn the controller OFF locate the toggle switch (1) on the left side of the control box and flip
downwards. The display and status light (13) will become inactive.