SPECIFICATIONS - Model Cascade
Page 22
Flue
Size
3”
Rear
Width, Overall
24” / 610mm
Depth, Overall Stove
22 1/8” / 562mm
Depth, w/3” Tee
28 ¼” / 718mm
Height, Overall
28 1/4” / 724mm
Height (Floor to Stove Top)
27 1/2” / 699mm
Floor to Rear
Flue Center
14” / 356mm
Facing Back of Unit,
Left Side to Center of Rear
Flue Outlet
6 3/4” / 172mm
Floor to Rear
Outside Air Inlet
11” / 279mm
Facing Back of Unit
Right Side to Center
of Air Inlet
5” / 127mm
Floor Protection
+ Front, Sides & Back = 6”
Requirements
Hopper Capacity
60 lbs.
Burn time
♦
17-40 hours
Fuse, Control Board
8 Amp, 250 Volt*
Heat Input (Max.)
♦
12,600-30,000 BTU / hr
Overall Efficiency
Up to 81%
Emissions
♦
1.3 gram / hr (varies w/
size and type of fuel)
EPA exempt
Ship Weight
165 lbs.
Convection Blower
102 CFM; 2.10 Amps,
(Room Air Blower)
2200 RPM
Auger Motor
1 RPM; .4 Amps
Combustion Blower
56 CFM; 2.10 Amps,
(Draft Inducer)
2200 RPM
BACK VIEW
SIDE VIEW
Note: Dimensions shown are approximations only
(+/- ¼”)
+
Non-combustible thermal rated floor protection must
be used when installed on carpet (see
Floor Protec-
tion
, page 5). When installed at clearances less
than 6”, the floor protector is only required to ex-
tend to the wall.
♦
Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb.
* Fuses are rated as “fast blow.”
To Stove
Top
Overall
Height