INSTALLATION
PAGE 13
INSTALLATION CONFIGURATIONS / STANDARD VENT-
ING OPTIONS
This appliance may be connected to an existing flue or
by installing type “PL” vent pipe (listed to UL 641 & ULC
S609). If a liner is run all the way to the top of the exist-
ing chimney, the existing flue should be sealed with a
steel plate. Start a vertical run with a Tee at the back of
the stove. Other options are illustrated below. Note: See
Vent Termination Requirements
on page 9.
Preferred Installation – Vertical Vent Through the Roof.
This venting configuration allows for the best stove
performance. The vertical pipe promotes natural draft
and with the chimney inside the dwelling, the flue
gases stay warm, thus rising at a consistent rate.
Exterior Vertical
Vent
Wall Straps
Required Every
4 ft. Minimum
Vertical Vent
Into A Masonry
Flue
Optional Complete
Liner and Listed Ter-
mination Cap
Optional Clean-Out
Access Door
Listed Rain Cap
Flashing
3” Min.
Clean-Out
Tee
Vertical
Vent
Through the
Roof
Interior Vertical
Vent into an Ex-
isting Class A
Chimney
Existing
Chimney Pipe
Pipe Increaser
3” Min.
Extend Pipe
to the Top if
Existing
Chimney is
Corroded or
Damaged