Lighting Stove With Fastfire
™
Self-Igniter:
1.
Fill the hopper with recommended pellet fuel and plug stove into wall outlet.
2.
Push the
Start
button on the control board to activate the igniter.
3.
Press the Auger
ON/OFF Switch
to the
“ON”
position.
4.
Pellets will start feeding into the grate and should begin to ignite within three to seven minutes. The self-
igniter will automatically shut-off after 15 minutes.
5.
If the auger system is not primed with pellets, as in a first time start-up or when the stove has completely
run out of fuel, it may take a few extra minutes to start. In these circumstances if the stove does not start after
the 15 minute ignition c ycle, unplug stove, plug back in and press start button.
6.
Air is drawn from the convection air system and is blown across the igniter element to produce a flow of
super heated air. This stream of air is directed through a hole in the back of the burn grate.
Tip:
set the blower speed (convection air) selector to a higher setting for better start-up.
7.
After the pellets are burning well, press the
HEAT OUTPUT
selector to the desired setting. Combustion air
and the pellet fuel feed rate will adjust automatically as the
HEAT OUTPUT
selector switch is pressed. The
flame should be bright yellow in color and there should be no evidence of soot formation at the top of the
flame. Press the Blower Speed switch to increase or decrease the desired amount of convection air from your
stove. If operating your stove with a wall thermostat, adjust the heat output selector switch to the desired
demand mode (#2 through #5 on the heat output selector switch).
Manual Lighting Procedure:
If it is ever necessary to light your stove manually the following procedure should be followed.
If Priming Is Required
1.
Fill the hopper with recommended pellet fuel and plug the stove into the wall outlet.
2.
Press the Start switch on the control panel. This will activate both blowers. Press the Auger
ON/OFF
switch on the control panel. This will activate the auger motor. Next, press the heat output switch to position
#5 (maximum feed rate).
3.
Look through the combustion chamber door and when you see the first pellets dropping into the grate the
auger is then fully primed. It will take 10 to 15 minutes to prime the auger.
4.
Once the auger is primed, unplug the stove to turn off the blowers and auger for a minimum of 30 seconds.
You need only do this when priming the auger. Once the stove is shut down, plug it into the wall outlet again.
Manual Starting Steps
1.
Place a recommended fire starter (see your dealer for appropriate fire starter) in the burn grate and put a
handful of pellets on top of the starter.
DO NOT USE FLAMMABLE LIQUIDS TO START YOUR STOVE.
2.
Light the fire starter in the grate with a match and close the door.
3.
After approximately 10 seconds, press the
START SWITCH
. You will notice that the fire will become
active and there will be air coming from the heat exchanger tubes.
4.
After the pellets in the grate are burning sufficiently (red hot coals), press the Auger
ON/OFF
switch:
this will activate the auger motor, and pellets will begin to feed into the burn grate. Your blower motors
will continue to operate.
5.
After the pellets are burning well, press the
HEAT OUTPUT
selector to the desired setting. Combustion
air and the pellet fuel feed rate will adjust automatically as the
HEAT OUTPUT
selector is pressed. The
flame should be bright yellow in color and there should be no evidence of soot formation at the top of
the flame. Press the Blower Speed switch to increase or decrease the desired amount of convection air
from your stove.
If operating your stove with a wall thermostat, adjust the heat output selector switch to the desired
demand mode (#2 through #5 on the heat output selector switch).
Turning Off Your Whitfield Pellet Stove:
Press the Auger
ON/OFF Switch
to turn the fuel feed of f. Pellets will stop feeding and the red light will stop
blinking. Both blowers will continue to operate. The blowers will automatically turn off after 30 to 45 minutes.
The low temperature switch will also shut the stove down safely if it runs out of fuel.
Operating Instructions