4
f.
For
Corner
Sections use the alignment bracket and screws supplied with
the continuous kit AOCMOKIT. Discard the CAM. With the gear tray of the
adjacent fittings dropped, slide the alignment bracket into one of the
adjacent fittings and secure using two of the screws supplied.
Slide the other alignment bracket into the other adjacent fitting but do not
secure with screws. The secured alignment bracket should be inline with
the suspension or ceiling bracket.
Remove the gear tray assembly using
three No. 2 pozi screwdrivers. Ensure the
screw driver pushes fully in to take the
weight off the geartray. Be careful not to
touch the LED,s. This step is not required for
infills.
g. For
Surface
. Use the M5x20mm screw to
lock the body to the ceiling bracket.
5. Continuous/corner fitting.
a. For
Corner
fitting
– hold the fittings together
and fit the remain screws to secure in place.
b. For
Continuous
straight fittings - turn the
cam using a 8mm flat screwdriver to clamp
the fittings together.
c. Place the foil tape provided on indicated
areas in black to
prevent light spill on both sides.
6. On standalone or continuous end of run fittings, endcaps will need installing.
Push endcap onto extrusion applying pressure when fixing with screws.
Once the endcap is installed cut the foil provided to shape and apply foil to the
black areas shown.
7. Electrical Connection (incoming)
Fixed Output
DALI with
Standard
Emergency
DALI
Fixed Output
with
Emergency
COMEPS
Fixed Output
DALI with
Standard
Emergency
Emergency
COMEPS
8. Through Cable Connection.
Standalone
options.
Through cable is redundant and should be ducted away neatly. Do not remove
terminal blocks.
For incoming cables use the
strain relief assembly as shown
right.
5