Air Flow

Furnace
Opening

Not to Exceed 20 

Air Flow

Electronic
Air Cleaner
Opening

Electronic
Air Cleaner

Furnace

Transition Section

(if Needed)

Figure 3

Cabinet

(Interchangeable)

Collecting Cell

(Interchangeable)

Collecting Cell

Outlet Box

Power Pack

Handle

Contact

Button

Contact

Button

Pre-Filters

(Interchangeable)

See text for Cell

Removal Clearance

Figure 4

SST1000

24 3/4

21 5/16 18 5/8 13 9/16 16 7/16 19 1/16

SST1400

29 11/16 26 1/4

23 5/8 13 9/16 16 7/16 19 1/16

SST1600

25 1/2

21 5/16 18 5/8

17 3/4

20 5/8

23 3/8

SST2000

29 11/16 26 1/4

23 5/8

17 3/4

20 5/8

23 3/8

MODEL NO.

A

B

C

D

E

F

Figure 5

LOCATING THE AIR FILTER

LOCATING THE AIR FILTER

LOCATING THE AIR FILTER

LOCATING THE AIR FILTER

LOCATING THE AIR FILTER

Your air filter must be mounted in the return air duct of a
central forced-air system, on the air entering side of your
furnace. (See Figure 3 for example.)

Select a location that meets the following:

1.

The face of the cell will be at a right angle to the air
stream.

2.

Allow the following clearances to permit removal of
cells and pre-filters: (See Figures 4 and 5)

Model SST1000 - 14 inches
Model SST1400 - 15 inches
Model SST1600 - 14 inches
Model SST2000 - 15 inches

For complete dimension data refer to Figure 5.

3.

The air filter is not to be placed in the discharge of
either the heating or cooling unit.

4.

IMPORTANT: 

IMPORTANT: 

IMPORTANT: 

IMPORTANT: 

IMPORTANT: If atomizing spray type humidifier is
used, it must be installed downstream from the air
filter.

5.

If the air cleaner has a power cord installed, unit must
be located close enought to the outlet so connection
can be made without the use of an extension cord.

If your furnace duct system has a pre-installed boot,
discard front cover of boot and slide the air cleaner
component inside the boot. For installation of Air Cleaner
Retrofit (ACR) kits, see page 13.

If furnace opening cannot be enlarged to required size, a
transition sheet metal section must be used. Transition
must be planned for each job. Reduction should not be
more than 4 inches per linear foot, approximately 20
angular degrees (Figure 3).

PREINST

PREINST

PREINST

PREINST

PREINSTALLA

ALLA

ALLA

ALLA

ALLATION

TION

TION

TION

TION

6 7/8"

A

B

E

D

F

C

Knockouts for

3/4" Conduit

(three sides)

DIRECTION OF AIR FLOW THROUGH

DIRECTION OF AIR FLOW THROUGH

DIRECTION OF AIR FLOW THROUGH

DIRECTION OF AIR FLOW THROUGH

DIRECTION OF AIR FLOW THROUGH

THE AIR CLEANER

THE AIR CLEANER

THE AIR CLEANER

THE AIR CLEANER

THE AIR CLEANER

Your air cleaner is shipped from the factory with air flow
from left-to-right. If this air flow is suitable for the
installation, no further changes need to be made (Fig-
ure 4). For right-to-left air flow, remove both pre-filter
and cell sections. Turn cells upside down (with the
same end facing the cabinet opening). This will locate
the ionizing wires at the right, and both contact buttons
and cell handles will be facing the power door. Air flow
direction must agree with arrow embossed on end of
collecting cells.

After installing the cell sections, install pre-filters in cabinet
tracks on the right. This will again place the pre-filters on
the air entering side (on the same side as ionizing wires).

Содержание Comfort Plus SST1000

Страница 1: ...rts Repair Parts Repair Parts Repair Parts Repair Parts PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F PART NO 37 6373F Replaces 37 6373E 0631 Please read and familiarize yourself...

Страница 2: ...Installation of this unit must comply with local electric Installation of this unit must comply with local electric Installation of this unit must comply with local electric Installation of this unit...

Страница 3: ...ot be removed by an Electronic Air Cleaner or by any other filtration media designed to remove airborne particles However some gases can be absorbed by an activated carbon filter or diluted with fresh...

Страница 4: ...5 If the air cleaner has a power cord installed unit must be located close enought to the outlet so connection can be made without the use of an extension cord If your furnace duct system has a pre i...

Страница 5: ...ing If duct connection to furnace allows less than nine inches for mounting the air cleaner shorten the lateral trunk or attach an offset fitting to the elbow HORIZONTAL FURNACE HORIZONTAL FURNACE HOR...

Страница 6: ...the furnace If necessary enlarge the opening in the furnace if possible to match the opening in the cabinet Ifthefurnaceopeningcannotbeenlarged atransition fitting should be used Figure 3 The cabinet...

Страница 7: ...ectors prop erly installed and grommets used to prevent wire abrasion Vertical Section Wood Block Tape All Joints Figure 16 Hot Neutral Grounding Conductor Front View Figure 17 Cabinet Pre Filters Han...

Страница 8: ...f the noise is objectionable push the ON OFF switch to the OFF position and allow additional time for cell s and pre filter s to dry In some cases the Operating Light will remain OFF during this initi...

Страница 9: ...Make sure wire is securely anchored at each end Support Ionizing Wire Figure 21 Rated Capacity 600 1200 cfm 1000 1600 cfm 1000 2000 cfm 1600 2200 cfm Max Pressure Drop 08 in W G 08 in W G 12 in W G 0...

Страница 10: ...misaligned ted misaligned Blower OFF A Remove power pack and clear contamination inside black bushing around Operating Light ON the small sensor element B Ensure small sensor element is centered in bu...

Страница 11: ...rovider Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor Failure to do so could result in reduced perfor...

Страница 12: ...th no cell attached 3 Place power pack on top of collecting cell ensuring that there is proper contact between the cell contact on the power pack contact 4 Using a standard extension cord apply 120 VA...

Страница 13: ...cting cell 2 Insert the two collecting cells into the cabinet behind the pre filters Be sure ionizing wires are directly behind the pre filters so the particles can be charged as soon as the air leave...

Страница 14: ...14 15 18 REP REP REP REP REPAIR P AIR P AIR P AIR P AIR PAR AR AR AR ARTS TS TS TS TS...

Страница 15: ...2 F858 1002 F858 1002 F858 1002 15 Cover Power Pack F16 8520 F16 8520 F16 8521 F16 8521 16 Manual 37 6373 37 6373 37 6373 37 6373 17 Charcoal Filter with mounting clips F825 0466 F825 0467 F825 0468 F...

Страница 16: ...lesaler or Original Equipment Manufac turer Sincerely White Rodgers Year JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ 20___ WASH RE...