Figure 4. Typical wiring diagram for single transformer systems

To prevent electrical shock and/or equipment
damage, disconnect electrical power at the main
fuse box until installation is complete. Verify
power is off with a voltmeter.

DO NOT EXCEED MAXIMUM VOLTAGE OR CUR-
RENT RATINGS. FIRE, PERSONAL INJURY, AND/
OR EQUIPMENT DAMAGE COULD RESULT.

NOTE

TABLE 2. WIRE IDENTIFICATION LABELS

1

G

G

1

9

Y1

Y1

9

2

C

C

2

3
L

L
3

4

R

R

4

5

O

O

5

6

B

B

6

7

E1

E1

7

8

E2

E2

8

10

Y2

Y2

10

11

W1

W1

11

12

W2

W2

12

13

W3

W3

13

14

S1

S1

14

15

S2

S2

15

16

S3

S3

16

affect thermostat operation.) If you are using existing
mounting holes, or if holes drilled are too large and do
not allow you to tighten subbase snugly, use plastic
screw anchors to secure subbase.

6.

Push excess wire into wall and plug hole with a fire-
resistant material (such as fiberglass insulation) to
prevent drafts from affecting thermostat operation.

WARNING

!

CAUTION

!

The following wiring diagrams show typical terminal
identification and wiring. For proper installation, refer to
the original manufacturers’ instructions.

Содержание 1F95W-71

Страница 1: ...acement Installation Remove Old Thermostat Attach Subbase to Wall Attach Thermostat to Subbase Operation 6 System Configuration Set Option Switches Check Thermostat Operation Fan Operation Heating Sys...

Страница 2: ...building temperature Observe the following general rules when selecting a location 1 Locate thermostat about 5 ft above the floor 2 Install thermostat on a partitioning wall not on an outside wall 3 N...

Страница 3: ...THE WALL 7 Install new thermostat using the following proce dures Attach Subbase To Wall 1 Remove the packing material from the thermostat Place the fingers of one hand on the center top and bottom po...

Страница 4: ...RSONALINJURY AND OR EQUIPMENT DAMAGE COULD RESULT NOTE TABLE 2 WIRE IDENTIFICATION LABELS 1 G G 1 9 Y1 Y1 9 2 C C 2 3 L L 3 4 R R 4 5 O O 5 6 B B 6 7 E1 E1 7 8 E2 E2 8 10 Y2 Y2 10 11 W1 W1 11 12 W2 W2...

Страница 5: ...HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made Damage to equipment will occur when power is restored IF SAFETY CIRCUITS ARE IN ONLY ONE...

Страница 6: ...the top of the thermostat and the 4 connector pins on the thermostat with the connectors near the top right section of the subbase when viewed from the front Gently pivot the thermostat down until the...

Страница 7: ...interruption or failure if the battery is not installed When power is restored the thermostat will automatically maintain a temperature of 64 F or a cooling temperatureof82 F factorypreprogrammed asne...

Страница 8: ...If you need further information about this product please write to White Rodgers Division Emerson Electric Co 9797 Reavis Road St Louis MO 63123 5398 Attention Technical Service Department...

Отзывы: