ATTENTION!

This product does not contain mercury.
However, this product may replace a unit
which contains mercury.

Do not open mercury cells. If a cell becomes
damaged, do not touch any spilled mercury.
Wearing non-absorbent gloves, take up the
spilled mercury with sand or other absorbent
material and place into a container which can
be sealed. If a cell becomes damaged, the
unit should be discarded.

Mercury must not be discarded in household
trash. When the unit this product is replacing
is to be discarded, place in a suitable
container and return to White-Rodgers at
2895 Harrison Street, Batesville, AR 72501
for proper disposal.

REMOVE OLD THERMOSTAT

Shut off electricity at main fuse or circuit
breaker box until installation is complete
AND the new thermostat is configured
properly.

Figure 1. Thermostat base and terminals

INSTALLATION

Remove the front cover of the old thermo-
stat. With wires still attached, remove wall
plate from the wall.

Identify each wire attached to the thermo-
stat
 using one of the labels enclosed with the
new thermostat.

Disconnect the wires from the old thermostat
one at a time. DO NOT let the wires fall
back into the wall.

Install the new thermostat using the follow-
ing procedures.

ATTACH BASE TO WALL

Remove packing material from the thermo-
stat. Place fingers of one hand on the center
top and bottom portion of the thermostat.
Grasp the base in the other hand on top and
bottom center and gently pull straight out.
Forcing or prying on the thermostat will
cause damage to the unit.

Place the base over the hole in the wall where
the wires come out and mark mounting hole
locations using the base as a template. Drill

3

¦

16

” pilot holes, and install screw anchors in

the wall.

Run wires through hole in base and attach
base to wall (see fig. 1).

Insert the wires into the terminals on the base
using the appropriate wiring diagram and
tighten the terminal screws.

CONFIGURING AND PROGRAM-
MING

The thermostat must be configured to operate
properly with the system. See the CON-
FIGURATION section of this manual.

This thermostat can be programmed for
automatic temperature control. Refer to
Operating Instructions for programming.

1

Mounting screws

2

Pull wires through this opening

3

Insert wires into terminal holes, then tighten screws

4

Screw anchors

5

Jumper connections for remote sensor power

(Do not remove)

2

Содержание 1F95CA-391

Страница 1: ...t or incorrect wiring will damage thermostat and could cause personal injury and or property damage Do not use on circuits exceeding specified voltage Higher voltage will damage thermostat and could cause shock or fire hazard Thermostat installation and all compo nents of the system shall conform to Class II circuits per the NEC code To prevent electrical shock and or equipment damage disconnect e...

Страница 2: ...es from the old thermostat one at a time DO NOT let the wires fall back into the wall Install the new thermostat using the follow ing procedures ATTACH BASE TO WALL Remove packing material from the thermo stat Place fingers of one hand on the center top and bottom portion of the thermostat Grasp the base in the other hand on top and bottom center and gently pull straight out Forcing or prying on t...

Страница 3: ...ection for proper thermostat configuration THERMOSTAT TERMINALS Upper L SA SB SC OT Malfunction Light Remote Sense A Remote Sense B Remote Sense C Outdoor Sensor Comfort Alert Interface Module THERMOSTAT TERMINALS Upper L SA SB SC OT Malfunction Light Remote Sense A Remote Sense B Remote Sense C Outdoor Sensor Comfort Alert Interface Module 3 THERMOSTAT TERMINALS Lower SYSTEM C R HM W2 DHM E W1 Y2...

Страница 4: ...YSTEM ONLY If you have a single stage compressor system see the diagram below A relay customer provided should be installed as shown in Fig 5 to switch the fan speed to the next lower speed on a call for dehumidification from the thermostat The reduction in air flow allows the coil to remove more humidity from the air The relay should be rated for blower motor load Since this configuration reduces...

Страница 5: ...h 6 step 6 is for heat pump only These items allow the cycle times in heating cooling and auxiliary heat pump systems only to be increased or decreased The factory set values can be adjusted higher for longer cycles or lower for shorter cycles NOTE Some manufacturers still instruct you to set the anticipator to the current draw of the equipment That instruction applies only to mercury bulb or mech...

Страница 6: ... in sequence after HEAT if HEAT PUMP is selected Program RUN TIME FWD Heat Pump ONLY TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD 6 SET CYCL AUX 08 1 to 40 9 HEAT FAN DELA OFF 00 0 to 127 seconds 10 PUMP ON OFF 11 COMP OFF DELA 60 0 to 99 7 COOL FAN DELA OFF 00 0 to 127 seconds 8 5 5 5 5 5 5 5 5 7 7 7 7 7 7 5 5 FAN DELA ON 01 1 to 30 seconds Selects time delay for fan ON Applies ...

Страница 7: ...nst premature compressor failure by locking out the compressor for at least five minutes after each cycle When the thermo stat is in compressor lockout the word COOL will flash on the display With heat pump systems the word HEAT will flash if the lockout occurs during a heat cycle During this period the compressor will not be energized COMFORT ALERT WITH ACTIVE PROTECTION Installer table step 16 T...

Страница 8: ...t service interval SERVICE REMINDER 8 1 Step Press Button s Displayed Press or to select COMMENTS Factory Default PAD TIME OFF Hrs or REM PAD TIME No of Hrs ON or OFF Set Humidifier Maintenance Reminder SERVICE 3 FLTR TIME OFF Hrs or REM FLTR TIME No of Hrs ON or OFF Set Air Filter Maintenance Reminder TIME FWD Service Button Menu Returns to Normal Operation PRGM RUN 2 SET PAD TIME 100 Hrs 25 to 1...

Страница 9: ...e and yellow for second stage EMERGENCY heat pump only Press SYSTEM to select EMER mode The LED indicator will glow red for first stage Aux in emergency mode A flashing red LED indicates a malfunction in the system HUMIDIFIER SYSTEM IF INSTALLED 1 Press SYSTEM until HEAT is shown at the top of the display 2 Press the HUMIDITY button once and release Then press the to the maximum humidity setpoint ...

Страница 10: ...t does not respond when keys are pressed or the thermostat is not operating properly you may use the reset button located on the back of the thermostat body see fig 2 Thermostat programming and configuration will not be affected by pressing the reset button However the clock will need to be reset RESETTING THERMOSTAT CONFIGURATION AND PROGRAMMING The thermostat can be reset back to default program...

Страница 11: ... the size Digital thermostats normally provide precise narrow or wide temperature swing of the Heating System equipment may be temperature control and may cycle faster than influencing the cycle rate someoldermechanicalmodels Afastercycle ratemeanstheunitturnsononoffmorefrequently but runs for a shorter time so there is no increase in energy use If you would like to increase the cycle time refer t...

Страница 12: ... will indicate HOLD and the number of hours remaining in the hold period will be indicated with the word HRS To adjust the length of time for the override press TIME FWD or TIME BACK The time you select will become the new number of hours for the Hold Til timing Once your time is selected let the thermostat revert back to normal operation on its own to accept the change Many furnaces have safety d...

Отзывы: