16
To adjust anticipation, press
SET
CLOCK
and
ADV
DAY
at the same time. The display will show
HEAT 5 (this is the factory preprogrammed
heating anticipation setting). You may se-
lect any anticipation setting from 4 to 40. If
the heat cycles are too short, press
TIME
FWD
to
increase the cycle time. If the heat cycles
are too long, press
TIME
BACK
to decrease the
cycle time. To set cooling anticipation, press
SET
CLOCK
and
ADV
DAY
at the same time again. The
display will show COOL 14 (factory
preprogrammed cooling anticipation).
Press
TIME
FWD
or
TIME
BACK
to adjust anticipation.
Press
RUN
PRGM
to return to your program.
• LOW BATTERY INDICATOR — The word
BATTERY will flash on the display if the 9
volt alkaline battery is low and should be
replaced.
• AUDIO PROMPTING — Each time you
press a button, the thermostat will beep
(this feature works only when the thermo-
stat is attached to the wall and 24VAC
power is present to the thermostat).
• BACKLIT DISPLAY — When you press
any button on the thermostat, the display is
lit for approximately eight seconds (this
feature works only when the thermostat is
attached to the wall and 24VAC power is
present to the thermostat).
• COMPRESSOR SHORT CYCLE PRO-
TECTION — To protect your compressor
from potential damage due to rapid cy-
cling, this thermostat has a built-in delay of
Содержание 1F95-80