5.

Keypad Lockout

Option switches #1, #2, and #4 should be changed (if
required), programming should be completed, and bat-
tery should be installed before changing option switch #3.

6.

Automatic Changeover from Heat to Cool

The battery maintains the stored program in the event of
a power failure. When attached to the wall with 24v AC
power applied, the thermostat will function normally with-
out the battery. However, the program will be lost in the
event of a power interruption or failure if the battery is not
installed. When power is restored, the thermostat will
automatically maintain a heating temperature of 64

°

F or

a cooling temperature of 82

°

F (factory preprogrammed)

as needed.

CHECK THERMOSTAT OPERATION

When checking thermostat, option switch #4 for auto-
matic changeover must be in the OFF position. This will
allow temporary setting of heat setpoints above cool
setpoints. After system checkout, reset option switch #4
to ON position if automatic changeover is desired (see
SET OPTION SWITCHES).

FAN OPERATION

1.

Turn on power to the system. If the auxiliary heat
source has a standing pilot, be sure to light it.

2.

Press 

FAN

SWITCH

 until FAN ON is displayed. The blower

should begin to operate.

3.

Press 

FAN

SWITCH

 until FAN AUTO is displayed. The

blower should stop operating within approximately
one minute.

HEATING SYSTEM

1.

Press 

SYSTEM

SWITCH

 until HEAT is displayed (it may al-

ready be displayed).

2.

Press 

 to adjust thermostat to 99

°

F. All stages of

the heating system should begin to operate within
approximately five minutes. However, if the PUMP
LED is flashing, the compressor lockout feature is
operating (see Lockout Bypass Option to tempo-
rarily override the compressor lockout feature during
testing).

COOLING SYSTEM

To prevent compressor and/or property damage,
if power to the compressor has been off or
interrupted for more than 1 hour and the outdoor
temperature is below 50

°

F, DO NOT operate the

system for at least the amount of time the com-
pressor was off!  This will allow the compressor
heaters to warm the compressor oils to avoid
damage due to slugging.

1.

Press 

SYSTEM

SWITCH

 until COOL is displayed.

2.

Press 

 to adjust thermostat to 40

°

F. All stages of

the cooling system should begin to operate within
approximately five minutes. However, if the PUMP
LED is flashing, the compressor lockout feature is
operating (see Lockout Bypass Option to tempo-
rarily override the compressor lockout feature during
testing).

NOTE

ON

1

2

3

4

Switch #1 (see steps 1-4)
Switch #2 (see steps 1-4)
Switch #3
Switch #4 (see step 6)

ON

ON

1

2

3

4

Switch #1 (see steps 1-4)
Switch #2 (see steps 1-4)
Switch #3 (see step 5)
Switch #4 ON

NOTE

NOTE

CAUTION

!

LOCKOUT BYPASS OPTION

FOR QUALIFIED SERVICE TECHNICIANS’ USE
ONLY.  OPERATORS SHOULD NOT USE THIS
FEATURE DUE TO POSSIBILITY OF EQUIPMENT
OR PROPERTY DAMAGE, OR PERSONAL INJURY.

COMPRESSOR SHORT TERM

CYCLE PROTECTION

This thermostat has a built-in short term (5-minute)
time delay.  During this 5-minute period, the thermo-
stat will lock out the compressor to allow head pres-
sure to stabilize.  If you want to override this feature

while testing thermostat operation, simply press 

VIEW

PRGM

and 

VIEW

TEMP

 buttons at the same time at initial startup.

DO NOT USE THE LOCKOUT BYPASS OPTION
UNLESS THE COMPRESSOR OIL HEATERS HAVE
BEEN OPERATIONAL FOR 6 HOURS AND THE
SYSTEM HAS NOT BEEN OPERATIONAL FOR AT
LEAST 5 MINUTES.

Содержание 1F94-71

Страница 1: ...Thermostat Ifindoubtaboutwhetheryourwiringismillivolt line orlow voltage have it inspected by a qualified heating and air conditioning contractor electrician or someone familiar with basic electricity...

Страница 2: ...or any temperature radiating equip ment 4 Avoid locations close to windows adjoining outside walls or doors that lead outside 5 Avoid locations close to air registers or in the direct path of air fro...

Страница 3: ...bottom portion of the thermostat Grasp the subbase in the other hand on the top and bottom center and gentlypullstraightout seefig 2 Thethermostathas pin and socket connectors Forcing or prying on th...

Страница 4: ...opening Connect wires under terminal screws Mounting hole 4 pin connector 9 pin connector O B Y1 Y2 C G W1 R W2 W3 Expansion plugs Figure 3 Subbase E1 E2 L DO NOT EXCEED MAXIMUM VOLTAGE OR CUR RENTRAT...

Страница 5: ...mostatically operated The accessory relay scheme is required when safety circuits exist in both systems Polarity must be observed If the HOT side of the second transformer is jumpered to the COMMON si...

Страница 6: ...ed and that excess wire is pushed into the wall Damage to the thermostat may occur if force is used OPERATION ENGAGE TWO UPPER GUIDES PIVOT DOWN Figure 7 Attaching thermostat to subbase SYSTEM CONFIGU...

Страница 7: ...ompressor lockout feature is operating see Lockout Bypass Option to tempo rarily override the compressor lockout feature during testing COOLING SYSTEM To prevent compressor and or property damage if p...

Страница 8: ...ale as described below Seller shall have the option of requiring the return of any defective Product transportation charges prepaid before recognizing any claim This warranty shall not apply to any Pr...

Отзывы: