This wall-mounted, low voltage thermostat maintains
room temperature by controlling the operation of multi-
stage systems.  Use this thermostat for applications
requiring up to three stages of heat and up to two stages
of cool.  Indicator lights show the system status.  The user
may program up to four time/temperature settings per 24
hour period.  The thermostat stores programs for seven
independent days. The thermostat will store both heating
and cooling programs simultaneously.  A 9 volt Energizer

®

battery will maintain the stored program for approximately
one week, if incoming power should fail.  If power failure
is extensive and the program is lost, after power restora-
tion, the thermostat will automatically maintain a factory
preprogrammed heating temperature of 64

°

F or a cooling

temperature of 82

°

F.

PART NO. 37-4744B

Replaces 37-4744A

9310

PRECAUTIONS

Operator:  Save these instructions for future use!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI  63123-5398

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

WHITE-RODGERS

1F94-71

 Multi-stage Electronic Digital Thermostat

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.

Do not exceed the specification ratings.

DESCRIPTION

W H I T E - R O D G E R S

DIGITAL COMFORT SET

II

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully.  Rough handling or distorting compo-
nents could cause the control to malfunction.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.

Do not use on circuits exceeding specified volt-
age.  Higher voltage will damage control and
could cause shock or fire hazard.

Do not short out terminals on gas valve or pri-
mary control to test.  Short or incorrect wiring will
burn out thermostat and could cause personal
injury and/or property damage.

CAUTION

!

WARNING

!

R

CONTENTS

Description .........................................................  1
Precautions ........................................................  1
Specifications .....................................................  2
Installation ..........................................................  2

New Installation

Select Thermostat Location
Route Wires to Location

Replacement Installation

Remove Old Thermostat
Attach Subbase to Wall
Attach Thermostat to Subbase

Operation ...........................................................  5

System Configuration

Set Option Switches

Check Thermostat Operation

Fan Operation
Heating System
Cooling System

Troubleshooting

INSTALLATION INSTRUCTIONS

Содержание 1F94-71

Страница 1: ...Thermostat Ifindoubtaboutwhetheryourwiringismillivolt line orlow voltage have it inspected by a qualified heating and air conditioning contractor electrician or someone familiar with basic electricity...

Страница 2: ...or any temperature radiating equip ment 4 Avoid locations close to windows adjoining outside walls or doors that lead outside 5 Avoid locations close to air registers or in the direct path of air fro...

Страница 3: ...bottom portion of the thermostat Grasp the subbase in the other hand on the top and bottom center and gentlypullstraightout seefig 2 Thethermostathas pin and socket connectors Forcing or prying on th...

Страница 4: ...opening Connect wires under terminal screws Mounting hole 4 pin connector 9 pin connector O B Y1 Y2 C G W1 R W2 W3 Expansion plugs Figure 3 Subbase E1 E2 L DO NOT EXCEED MAXIMUM VOLTAGE OR CUR RENTRAT...

Страница 5: ...mostatically operated The accessory relay scheme is required when safety circuits exist in both systems Polarity must be observed If the HOT side of the second transformer is jumpered to the COMMON si...

Страница 6: ...ed and that excess wire is pushed into the wall Damage to the thermostat may occur if force is used OPERATION ENGAGE TWO UPPER GUIDES PIVOT DOWN Figure 7 Attaching thermostat to subbase SYSTEM CONFIGU...

Страница 7: ...ompressor lockout feature is operating see Lockout Bypass Option to tempo rarily override the compressor lockout feature during testing COOLING SYSTEM To prevent compressor and or property damage if p...

Страница 8: ...ale as described below Seller shall have the option of requiring the return of any defective Product transportation charges prepaid before recognizing any claim This warranty shall not apply to any Pr...

Отзывы: