ATTACH THERMOSTAT TO SUBBASE

IT IS RECOMMENDED THAT YOU SET OPTION
SWITCHES TO DESIRED POSITION BEFORE ATTACH-
ING ON SUBBASE 
(see OPERATION). IT IS ALSO
RECOMMENDED THAT YOU PROGRAM THE
THERMOSTAT WITH BATTERY INSTALLED BEFORE
ATTACHING ON SUBBASE 
(see OPERATION GUIDE
for programming instructions).

POWER TO THERMOSTAT MUST BE OFF BEFORE
ATTACHING THERMOSTAT TO WALL. FAILURE TO
TURN OFF POWER BEFORE ATTACHING THERMO-
STAT MAY CAUSE EQUIPMENT DAMAGE DUE TO
RAPID COMPRESSOR CYCLING.

To attach thermostat to subbase, line up the plastic snap
guides at the top of the thermostat and the 4 connector
pins on the thermostat with the connectors near the top
right section of the subbase (when viewed from the front).
Gently pivot the thermostat down until the 9-pin connec-

tors and the plastic snaps lock into place (see fig. 7). Be
gentle when attaching thermostat
. If the thermostat
does not seem to be attaching to the subbase easily,
make sure that the connector pins and plastic snaps are
properly aligned, and that excess wire is pushed into the
wall. Damage to the thermostat may occur if force is
used.

SYSTEM CONFIGURATION

ANY TIME AN OPTION SWITCH IS CHANGED, THE 9
VOLT ENERGIZER

®

 BATTERY MUST BE REMOVED

FOR A MINIMUM OF 2 MINUTES.

SET OPTION SWITCHES

1.

Multi-stage Systems — up to 3 heat stages and 2
cool stages

2.

Electric Heat Systems

3.

Economizer — 1st stage cooling

4.

Automatic Changeover from Heat to Cool

The battery maintains the stored program in the event of
a power failure. When attached to the wall with 24 VAC
power applied, the thermostat will function normally with-
out the battery. However, the program will be lost in the
event of a power failure or interruption if the battery is not
installed. When power is restored, the thermostat will
automatically maintain a heating temperature of 64

°

F or

a cooling temperature of 82

°

F (factory preprogrammed)

as needed.

ENGAGE TWO UPPER GUIDES;

PIVOT DOWN

Figure 7.  Attaching thermostat to subbase

OPERATION

NOTE

NOTE

ON

1

2

3

4

Switch #1
Switch #2
Switch #3 (see step 3)
Switch #4 (see step 4)

ON
ON

ON

1

2

3

4

Switch #1
Switch #2
Switch #3 (see step 3)
Switch #4 (see step 4)

ON
OFF

ON

1

2

3

4

Switch #1 (see steps 1-2)
Switch #2 (see steps 1-2)
Switch #3
Switch #4 (see step 4)

ON

ON

1

2

3

4

Switch #1 (see steps 1-2)
Switch #2 (see steps 1-2)
Switch #3 (see step 3)
Switch #4 ON

Figure 8. Back of thermostat

Option switches

9-pin connector

4-pin connector

Battery

Содержание 1F91W-71

Страница 1: ...of 64 F or a cooling temperature of 82 F INSTALLATION INSTRUCTIONS WHITE RODGERS Ifindoubtaboutwhetheryourwiringismillivolt line orlow voltage have it inspected by a qualified heating and air conditi...

Страница 2: ...any temperature radiating equip ment 4 Avoid locations close to windows adjoining outside walls or doors that lead outside 5 Avoid locations close to air registers or in the direct path of air from th...

Страница 3: ...packing material from the thermostat Place the fingers of one hand on the center top and bottom portion of the thermostat Grasp the subbase in the other hand on the top and bottom center and gently p...

Страница 4: ...stic expansion plugs to secure subbase 6 Push excess wire into wall and plug hole with a fire resistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation DO...

Страница 5: ...st be observed If the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made Damage to equipment will occur when power is restored Relay contac...

Страница 6: ...used SYSTEM CONFIGURATION ANY TIME AN OPTION SWITCH IS CHANGED THE 9 VOLT ENERGIZER BATTERY MUST BE REMOVED FOR A MINIMUM OF 2 MINUTES SET OPTION SWITCHES 1 Multi stage Systems up to 3 heat stages and...

Страница 7: ...sor heaters to warm the compressor oils to avoid damage due to slugging 1 Press SYSTEM HEAT OFF COOL AUTO until COOL is displayed 2 Press to adjust the thermostat to 40 F All stages of the cooling sys...

Страница 8: ...If you need further information about this product please write to White Rodgers Division Emerson Electric Co 9797 Reavis Road St Louis MO 63123 5398 Attention Technical Service Department...

Отзывы: