PART NO. 37-5519A

9522

1F91W-71

 Multi-stage Electronic Digital Thermostat

PRECAUTIONS

Operator:  Save these instructions for future use!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

This wall-mounted, low voltage thermostat maintains
room temperature by controlling the operation of multi-
stage systems. Use this thermostat for applications re-
quiring up to three stages of heat and up to two stages of
cool. Indicator lights show the system status. The user
may program up to four time/temperature settings per 24
hour period. The thermostat stores settings for a five-day
(weekday) program and a two-day (weekend) program.
The thermostat will store both heating and cooling pro-
grams simultaneously. A 9 volt Energizer

®

 battery will

maintain the stored program for approximately one week,
if incoming power should fail. If power failure is extensive
and the program is lost, after power restoration, the
thermostat will automatically maintain a factory
preprogrammed heating temperature of 64

°

F or a cooling

temperature of 82

°

F.

INSTALLATION INSTRUCTIONS

WHITE-RODGERS

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.

Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring will
burn out thermostat and could cause personal
injury and/or property damage.

WARNING

!

CAUTION

!

CONTENTS

Description .......................................................... 1
Precautions ......................................................... 1
Specifications ...................................................... 2
Installation ........................................................... 2

New Installation

Select Thermostat Location
Route Wires to Location

Replacement Installation

Remove Old Thermostat
Attach Subbase to Wall
Attach Thermostat to Subbase

Operation ............................................................ 6

System Configuration

Set Option Switches

Check Thermostat Operation

Fan Operation
Heating System
Cooling System

Troubleshooting

Содержание 1F91W-71

Страница 1: ...of 64 F or a cooling temperature of 82 F INSTALLATION INSTRUCTIONS WHITE RODGERS Ifindoubtaboutwhetheryourwiringismillivolt line orlow voltage have it inspected by a qualified heating and air conditi...

Страница 2: ...any temperature radiating equip ment 4 Avoid locations close to windows adjoining outside walls or doors that lead outside 5 Avoid locations close to air registers or in the direct path of air from th...

Страница 3: ...packing material from the thermostat Place the fingers of one hand on the center top and bottom portion of the thermostat Grasp the subbase in the other hand on the top and bottom center and gently p...

Страница 4: ...stic expansion plugs to secure subbase 6 Push excess wire into wall and plug hole with a fire resistant material such as fiberglass insulation to prevent drafts from affecting thermostat operation DO...

Страница 5: ...st be observed If the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made Damage to equipment will occur when power is restored Relay contac...

Страница 6: ...used SYSTEM CONFIGURATION ANY TIME AN OPTION SWITCH IS CHANGED THE 9 VOLT ENERGIZER BATTERY MUST BE REMOVED FOR A MINIMUM OF 2 MINUTES SET OPTION SWITCHES 1 Multi stage Systems up to 3 heat stages and...

Страница 7: ...sor heaters to warm the compressor oils to avoid damage due to slugging 1 Press SYSTEM HEAT OFF COOL AUTO until COOL is displayed 2 Press to adjust the thermostat to 40 F All stages of the cooling sys...

Страница 8: ...If you need further information about this product please write to White Rodgers Division Emerson Electric Co 9797 Reavis Road St Louis MO 63123 5398 Attention Technical Service Department...

Отзывы: