EXAMPLE: 

MO TU WE TH FR

This display window shows that for the 1st weekday period,
the start time is 6:00 AM, and 70

°

 is the programmed

temperature (this example reflects factory preprogramming).

4. Press 

 or 

 to change the displayed temperature to your

selected temperature for the 1st heating program period.

5. Press SET TIME once (the programmed time will flash).

Press 

 or 

 until your selected time is displayed. The time

will change in 15 minute increments. When your selected
time is displayed, press SET TIME again to return to the
change temperature mode.

6. Press VIEW PRGM once. The currently programmed start

time and setpoint temperature for the 2nd heating program
period will be displayed.

7. Repeat steps 4 and 5 to select the start time and heating

temperature for the 2nd heating program period.

8. Repeat steps 4 through 6 for the 3rd and 4th heating program

periods. Weekday heating programs are now complete.

9. Press VIEW PRGM once. “SA SU” (indicating weekend

program) will be displayed, along with the start time for the
1st heating period and the currently programmed tempera-
ture.

10. Repeat steps 4 through 8 to complete weekend heating

programming.

11. When you have completed entering your heating program,

press RUN PRGM.

Enter Cooling Program

If the outside temperature is below 50

°

F, disconnect

power to the cooling system before programming.
Energizing the air conditioner compressor during
cold weather may cause personal injury or property
damage.

1. Press SYSTEM button until COOL is displayed.

2. Follow the procedure for entering your heating program,

using your selected cooling times and temperatures.

CAUTION

!

CHECK YOUR PROGRAMMING

Follow these steps to check your thermostat programming one
final time before beginning thermostat operation.

1. Press SYSTEM button until HEAT is displayed.

2. Press VIEW PRGM to view the 1st weekday heating period

time and temperature. Each time you press VIEW PRGM,
the next heating period time and temperature will be dis-
played in sequence for weekday, then weekend program
periods (you may change any time or temperature during this
procedure).

3. Press RUN PRGM.

4. Press SYSTEM button until COOL is displayed.

5. Repeat step 2 to check cooling temperatures.

6. Press RUN PRGM to begin program operation.

7. Press SYSTEM button to select HEATCOOL, or AUTO

mode.

YOUR THERMOSTAT IS NOW COMPLETELY PRO-
GRAMMED AND READY TO AUTOMATICALLY PROVIDE
MAXIMUM COMFORT AND EFFICIENCY!

During normal operation, the second stage of heat or cool may
take 15 to 30 minutes to turn on. The delay varies depending on
the performance of the first stage. Typically the second stage will
come on sooner in more severe weather, while in milder weather
it will take longer. There is no adjustment to this feature, as it is
designed to maximize both comfort and efficiency.

TROUBLESHOOTING

If your thermostat’s display is frozen or displaying incorrectly,
the thermostat may have been affected by static discharge or
voltage variations. If this happens, press the RESET button (see
fig. 2, page 2 for the location of the button). Pressing the RESET
button will clear all user programming. The thermostat will revert
to factory preprogramming. You will need to reset the time and,
if desired, reprogram the thermostat to your selected program.
If pressing the RESET button does not correct the problem,
contact a qualified service technician.

For optimum performance, we recommend replacing batteries
once a year with fresh “AA” Energizer

®

 alkaline batteries.

NOTE

Содержание 1F81-71

Страница 1: ...Optional B and O terminals Preprogrammed temperature control LCD continuously displays set point and alternately dis plays time and room temperature Temperature override until next program period Man...

Страница 2: ...stheEnergyManagementRecov ery EMR feature EMR allows the thermostat to energize the heating system up to 30 minutes before the time pro grammed into the thermostat The thermostat will then energize th...

Страница 3: ...fety circuits Fan Relay G TRANSFORMER Compressor Contactor Stage 2 24 VAC 120 VAC Hot Neutral TRANSFORMER TWO COMMONS MUST BE JUMPERED TOGETHER CUT AND TAPE OFF The 24 Volt neutral connection to termi...

Страница 4: ...if you have a two stage cooling system NOTE CAUTION LOCKOUT BYPASS OPTION FOR QUALIFIED SERVICE TECHNICIANS USE ONLY OPERATORSSHOULDNOTUSETHISFEA TURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMA...

Страница 5: ...STORAGE When programming you can enter both your heating and cooling programs at the same time There is no need to reprogram the thermostat at the beginning of each season Figure 6 Thermostat display...

Страница 6: ...also want to look at the sample program table to get an idea of how the thermostat can be programmed Entering Your Program Follow these steps to enter the heating and cooling programs you have select...

Страница 7: ...YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before beginning thermostat operation 1 Press SYSTEM button until HEAT is displayed 2 Press VIEW PRGM to view t...

Страница 8: ......

Отзывы: