White Rodgers 1F81-71 Скачать руководство пользователя страница 1

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test.  Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Printed in U.S.A.

DESCRIPTION

1F81-71

Programmable Electronic

Digital Automatic Changeover Multi-stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-5938B

Replaces 37-5938A

9912

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Your new White-Rodgers 5-Day/2-Day Digital Multi-stage Ther-
mostat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design heating and cooling programs that fit
your needs.

Features:

• Separate 5-day (weekday) and 2-day (weekend) programming

with four separate time/temperature periods per program

• Simultaneous heat and cool program storage
• Optional C terminal (dual power option)
• Optional Energy Management Recovery (EMR)

PRECAUTIONS

SPECIFICATIONS

• Optional B and O terminals
• Preprogrammed temperature control
• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period
• Manual program override (HOLD temperature)

°

F/

°

C convertibility

• Temperature range 45

°

 to 90

°

F

• Two-stage heat/two-stage cool
• Armchair programming  capability

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system.  If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

ELECTRICAL DATA
Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
2.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

• Heat/cool systems with up to two stages heat, two

stages cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 2.5 amps
• 3-wire zoned hydronic heating systems

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

Содержание 1F81-71

Страница 1: ...Optional B and O terminals Preprogrammed temperature control LCD continuously displays set point and alternately dis plays time and room temperature Temperature override until next program period Man...

Страница 2: ...stheEnergyManagementRecov ery EMR feature EMR allows the thermostat to energize the heating system up to 30 minutes before the time pro grammed into the thermostat The thermostat will then energize th...

Страница 3: ...fety circuits Fan Relay G TRANSFORMER Compressor Contactor Stage 2 24 VAC 120 VAC Hot Neutral TRANSFORMER TWO COMMONS MUST BE JUMPERED TOGETHER CUT AND TAPE OFF The 24 Volt neutral connection to termi...

Страница 4: ...if you have a two stage cooling system NOTE CAUTION LOCKOUT BYPASS OPTION FOR QUALIFIED SERVICE TECHNICIANS USE ONLY OPERATORSSHOULDNOTUSETHISFEA TURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMA...

Страница 5: ...STORAGE When programming you can enter both your heating and cooling programs at the same time There is no need to reprogram the thermostat at the beginning of each season Figure 6 Thermostat display...

Страница 6: ...also want to look at the sample program table to get an idea of how the thermostat can be programmed Entering Your Program Follow these steps to enter the heating and cooling programs you have select...

Страница 7: ...YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before beginning thermostat operation 1 Press SYSTEM button until HEAT is displayed 2 Press VIEW PRGM to view t...