WIRING 

SETTING THE DIAL 

All wiring must conform to local and national electrical codes and ordinances.
Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided, the following repre-
sents a typical installation.

The movable indicator (D) points to the temperature at which 
the  compressor  starts.  The  fixed  indicator  (B)  points  to  the 
temperature at which the compressor will stop. The difference 
between these two indicators is the differential. Follow these 
instructions to set the dial:

1.  Insert a screwdriver in the adjusting slot (A) and turn the 

dial until the fixed indicator (B) points to the temperature at 
which the compressor is to stop.

2.  Turn the differential adjusting screw (C) until the movable 

indicator (D) points to the temperature at which the com-
pressor is to start.

Temperature

control

Low

temperature

limit

High side

pressure control

(if used)

To

Compressor

Motor

Line

L1

L2

Note: Make L1 “HOT” on 

120V installation

Circuit showing temperature control control-
ling compressor directly.

Temperature

control

Low temperature

limit

Suction

pressure

control

High side

pressure

control

Motor

starter

Solenoid

refrigerant

valve

To

Compressor

Motor

Line

L1

L2

Note: Make L1 “HOT” on 120V installation

Circuit showing temperature control to open and close refrigerant valve. Suction 
pressure control starts and stops compressor through motor starter.

"B" Fixed indicator

(cut-out point)

"C" Differential

adjusting screw

"D" Movable indicator

(cut-in point)

"A" Adjusting

slot

Controls with one circuit (two terminals)

Controls with two circuits (three terminals)

BLUE

RED

WHITE

240V

22.2A

22.2A

LOAD CONDITIONS

MAXIMUM ALLOWABLE RATING

Full Load

Locked Rotor

120V

7.4A

7.4A

120V

44.5A

44.5A

240V

3.7A

3.7A

Load between Blue and Red 
terminals must not exceed:
Load between Blue and White 
terminals must not exceed:

To

Additional

Units

B R

W

B R

W

Valve

No. 2

Valve

No. 1

Blue
White
Red

To

Compressor

Motor

Line

L1

L2

Note: Make L1 “HOT” on 

120V installation

Temperature

control

Temperature

control

Low

temperature

limit

Low

temperature

limit

This diagram shows a typical two-circuit 
application.  Several  zones  receive  re-
frigeration  from  the  same  compressor, 
but each zone requires its own solenoid 
refrigerant valve, temperature control and 
limit control.

Typical Refrigeration Pump Down Circuit

The blue terminal is common. The table below shows the maxi-
mum load allowed between terminals.

Содержание 1609 Series

Страница 1: ...nt from the dial setting Refrigeration and temperature controls are calibrated and tested under controlled manufacturing conditions Published specifications do not include normal manufacturing specifi...

Страница 2: ...igh side pressure control Motor starter Solenoid refrigerant valve To Compressor Motor Line L1 L2 Note Make L1 HOT on 120V installation Circuit showing temperature control to open and close refrigeran...

Страница 3: ...publi es n incluent pas les sp cifications de fabrication standard De l gers carts de performance peuvent survenir selon les changements de conditions PR CAUTIONS Op rateur Il faut conserver ces instr...

Страница 4: ...seur mais chaque zone doit avoir une lectrovanne de frigorig ne et une commande de temp rature qui lui sont propres B Fixed indicator cut out point C Differential adjusting screw D Movable indicator c...

Страница 5: ...sdemanufactura Lasespecificacionespublicadasnoincluyenlasespecificaciones normalesdemanufactura Sepuedenesperardiferenciasmeno res en el rendimiento con el cambio de condiciones PRECAUCIONES Operador...

Страница 6: ...asta que el indicador movible D se ale a la temperatura a la cual el compresor tiene que arrancar B Fixed indicator cut out point C Differential adjusting screw D Movable indicator cut in point A Adju...

Страница 7: ...NOTES...

Страница 8: ...hite Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co www white rodgers com www emersonclimate com Homeowner Help Line 1 800 284 292...

Отзывы: