Leak Detection
There are a few different types of leak detection available depending on the model of
your pump. Please locate the type of pump and shuttle you have below to determine
how to connect the leak detection.
Internal Muffler Design (Bottom Mounted)
For the internal muffler design remove the 2ea ¼ npt plugs located on the bottom (above)
or face (below) of the shuttle valve. Next insert the Leak Adapters into the two open
ports. The ¼” npt plugs can now be replaced into the bottom of the Leak Adapters for
bottom mounted (above) and into the face for face mounted (below). Next remove the
PFA Leak Detect Probes from the PFA encapsulated fibers and screw them into the open
ports on the side of the leak adapters until they become snug. The PFA encapsulated
fibers can then be re-inserted back into the probes until they bottom out. The gripper
nuts can then be tightened up to lock the PFA encapsulated fibers into place. If pump is
already installed it may be necessary to remove the shuttle valve from pump in order to
attach the Leak Adapters.