25
TROUBLESHOOTING/SPECIFICATION
Overload LED on
Problem Solution
Equipment has a high
Turn inverter power switch
start up surge.
OFF (O) and then ON (l)
again until the inverter
powers your appliance.
Repeat as necessary
to get your appliance
“started”.
Battery voltage below
Recharge or replace
10 volts.
battery.
Equipment being operated Use a higher capacity
draws too much power.
inverter.
Inverter is too hot (thermal
Allow inverter to cool.
shutdown mode).
Check for adequate
ventilation. Reduce the
load on the inverter to
rated continuous power
output.
XP1200i INVERTER SPECIFICATIONS
Maximum Continuous Power .............................................. 1200 Watts
Maximum Surge Capability (Peak Power) .......................... 2400 Watts
*
No Load Current Draw ................................................................ < 1.0A
Waveform .............................................................. Modified Sine Wave
Operating Input Voltage Range ............................. 11-15+0.5 Volts DC
AC Receptacle .................................... Three North American 3 Prong
USB Port .......................................................................... 5 V 2.1A Max
Approximate Dimensions .............................. 8.9” L x 7.4” W x 3.54” H
Approximate Weight ................................................................... 4.5 lbs