RECEIVING AND INSPECTING THE UNIT

Upon Receiving the WhisperKOOL Cooling Unit

•  Lift only at the designated hand hold locations on the shipping container or fully support the unit from underneath.  

A shipment may include one or more boxes containing accessories. 

•  Inspect the packaging for any obvious signs of damage or mishandling before opening the container. 

•  Note any discrepancies or visual damage on the Bill of Lading before signing. 

•  Place the box containing the WhisperKOOL unit on a tabletop to prepare it for testing prior to installing. 

•  Sit unit upright for 24 hours. 

Note: 

WhisperKOOL units are manufactured in the USA and tested prior to shipment. 

Review the Packing Slip to Verify Contents

•  Check the model number to ensure it is correct. 

•  Check that all factory options ordered are listed. 

If any items listed on the packing slip do not match your order information,  

contact WhisperKOOL Customer Service immediately. 

Check the Box for the Following Contents: 

Please leave the WhisperKOOL unit in its original box until you are ready for installation. This will allow you to move the product 

safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions. 

TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit. 

2000i / 3000i / 4000i

Single Piece Mounting Bracket
Accessory Kit One: 

•  WhisperKOOL Owner’s Manual
•  Bypass Plug 
•  Bottle Temperature Probe

Accessory Kit Two: 

•  8’ Power Cord 
•  Mounting Bracket Insulation Foam 14.5” (2) 
•  Mounting Bracket Insulation Foam 18” (2) 
•  1¾ Standard Screws (11) 
•  ½ Self-Tapping Screws (6) 
•  ³�₈ x ¼ Barbx FNPT Fitting
•  Drain Line Tube (1) 
•  Connection “T” (1)
•  Magnetic Deflectors for Airflow Control (2)

6000i / 8000i

Single Piece Mounting Bracket
Accessory Kit One: 

•  WhisperKOOL Owner’s Manual
•  Bypass Plug
•  Bottle Temperature Probe

Accessory Kit Two: 

•  Power Cord
•  Mounting Bracket Insulation Foam 14.5” (2) 
•  Mounting Bracket Insulation Foam 25” (2) 
•  1¾ Standard Screws (11) 
•  ³�₈ Self-Tapping Screws (6) 
•  ³�₈ x ¼ Barbx FNPT Fitting
•  Drain Line Tube (1) 
•  Connection “T” (1)
•  Magnetic Deflectors for Airflow Control (2)

Содержание SC 2000i

Страница 1: ...SC SERIES OWNER S MANUAL SC 2000i SC 3000i SC 3000i SC 4000i SC 6000i SC 8000i The Coolest Thing In Wine Storage...

Страница 2: ...esponsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinoth...

Страница 3: ...Through the Wall Installation 12 Preparing the Installation Location 12 Preparing the Unit for Installation 13 Installing the Unit 14 Condensation Drain Line 15 Liquid Measuring Thermostat System 16...

Страница 4: ...SC 060815 Page 2 1 800 343 9463 QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Bottle Probe Probe Input Control Panel see page 10 for details Drain Port Rear Power Inlet...

Страница 5: ...Partially Ducted Thermostat Digital control display Temp Delta 30 F temperature differential maintains proper cellar temperature when exhaust environment does not exceed 85 F Outside Venting Not Recom...

Страница 6: ...Cooling Unit The WhisperKOOL cooling unit is a specialized refrigeration unit designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and...

Страница 7: ...heck the Box for the Following Contents Please leave the WhisperKOOL unit in its original box until you are ready for installation This will allow you to move the product safely without damaging it Wh...

Страница 8: ...n the temperature of the cellar over time by cycling cooler air throughout Test the unit prior to installation 6 It is Required to install a drain line to remove condensation from the unit 7 The Whisp...

Страница 9: ...ceilings are insulated to keep the cellar temperature as consistent as possible during the summer and winter months The R value or quality of insulation is determined by the rate at which heat passes...

Страница 10: ...ve a very good seal to keep the cool cellar air from escaping out of the cellar One of the most common problems with cooling units running continually is due to the door not sealing properly In cases...

Страница 11: ...generated on the exhaust side of the unit Adequate ventilation is required in order to dissipate heat away from the unit If ventilation is inadequate the exhaust will heat the area or room and adverse...

Страница 12: ...sperKOOL unit into a surge protector or power conditioner As with any sensitive electrical equipment the WhisperKOOL electrical equipment may be damaged by power surges and spikes Power surges and spi...

Страница 13: ...uations Mounting the system lower in the cellar Flush mounting the condenser side of system Directing airflow to avoid recirculation Apply the Magnetic Deflectors in one of the positions displayed bel...

Страница 14: ...he second horizontal cut from stud to stud on the line 16 below the first cut Once the horizontal lines have been cut make vertical cuts using the inside edge of the studs as a guide Once both vertica...

Страница 15: ...diagram below This location determines the depth of the installation For example position 1 keeps most of the unit out of the cellar while position 2 makes the back of the unit near flush on the exter...

Страница 16: ...all Secure the flange to the wall through the pre drilled holes The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL unit see i...

Страница 17: ...ll void the warranty on the unit Drain Line All units come with a drain line for additional removal of excessive condensate It is mandatory to install the drain line with a T fitting During operation...

Страница 18: ...sistent temperature place bottle probe approximately 3 feet away from the air output and not in the flow of the air To Use the Thermostat 1 Locate an empty wine bottle 2 Fill 3 4 full with room temper...

Страница 19: ...ll then return to normal operation If the evaporator is not above 26F after the Anti Frost sequence has ended the red error light will display in the upper right corner Alarm Ad3 will be recorded in t...

Страница 20: ...Set Point Pb1 Liquid Temperature Pb2 Evaporator Coil Temperature Pb3 Condenser Coil Temperature Press the SET button again to view any of these values To change the set point press the SET button Whe...

Страница 21: ...it and allow the coil to thaw before re starting 2 Make sure the room to which the unit is exhausting is not less than 60 F 3 If the unit continues to go into continuous Anti Frost cycles every 5 minu...

Страница 22: ...White White Ground POWER SUPPLY 115 VAC 60 Hz 20 A POWER CORD Evap Fan Blue Green 1 2 3 4 5 6 7 8 9 10 11 1 4 2 5 3 6 1 4 1 4 Line Black Line White Black Evap Probe Bottle Probe Cond Probe FRONT REAR...

Страница 23: ...ain line to see if it is above the waterline when draining into a vessel Quarterly 1 Use a vacuum with brush attachment to clean coils Be careful not to crush coil fins when cleaning Annually 1 Inspec...

Страница 24: ...point Power select switch in wrong position See page 10 for correct switch position Faulty thermostat or wiring Call Customer Service at 1 800 343 9463 Cellar Temperature is to Warm Possible Cause So...

Страница 25: ...463 Evaporator Fan Runs But Compressor Does Not Possible Cause Solution Running an Anti Frost cycle Check evaporator coil temperature Compressor and or starting components faulty Call Customer Service...

Страница 26: ...oll Free 1 800 343 9463 Fax 209 466 4606 ACCESSORIES FOR COOLING UNITS WhisperKOOL offers accessories to enhance and customize your wine cooling unit Exterior Grille The exterior grille protects the u...

Страница 27: ...www whisperkool com Page 25 SC Series NOTES...

Страница 28: ...t to the End User and 2 PARTS Supply to the End User new or rebuilt replacement parts for the Product in exchange for the return of defective parts and 3 FREIGHT Cover normal ground freight charges fo...

Страница 29: ...ry the limited warranty on this Product 3 Product Installation Requirements A Prior to installing a WhisperKOOL Product the End User must read the WhisperKOOL Owner s Manual and thereafter the End Use...

Страница 30: ...8 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a Produ...

Страница 31: ...l Assistance WhisperKOOL Customer Service is available Monday through Friday from 6 00 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and warran...

Страница 32: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...

Отзывы: