WhisperKool PLATINUM MINI Скачать руководство пользователя страница 49

WhisperKOOL Product Terms and Conditions  

Including Product Limited Warranty And Product Installation Requirements 

For WhisperKOOL Split System Series

ATTENTION:  PLEASE  READ  THESE  TERMS  OF  USE  CAREFULLY  BEFORE  INSTALLING  YOUR  WHISPERKOOL  COOLING 

SYSTEM. INSTALLING YOUR WHISPERKOOL COOLING SYSTEM INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF 

THE TERMS AND CONDITIONS SET FORTH HEREIN (“TERMS OF USE”). IF YOU DO NOT ACCEPT THESE TERMS OF USE, YOU 

RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND REPLACEMENT COSTS.

1. Purchase of a WhisperKOOL Cooling System assumes that the Purchaser (“End User”) fully accepts and

agrees to the Terms and Conditions set forth in this document. The Terms and Conditions of Sale and

Owner’s Manual are shipped with each unit and, if another copy is needed, replacement copies can be 

downloaded from the company website (whisperkool.com) or by contacting WhisperKOOL directly for a 

new copy. WhisperKOOL reserves the right, in its sole discretion, to change its Terms and Conditions at any 

time, for any reason, without notice.

2. WhisperKOOL Product Installation and Limited Warranty

A. Purchaser of the product must arrange for the product to be installed by a certified HVAC/R technician in accordance with

procedures set forth by WhisperKOOL and described in the WhisperKOOL Owner’s Manual.

B. The HVAC/R technician installing the product must complete the designated portion of the Split Startup Checklist and

provide licensing or certification identification number information to assist in the warranty registration process.

C. Purchaser  must  return  the  completed  Split  Startup  Checklist  to WhisperKOOL  within  thirty  (30)  days  of  installation  of

Product. The  Split  Startup  Checklist  must  be  approved  by WhisperKOOL  to  activate  the  Limited Warranty.  If  the  Split

Startup Checklist is approved, Purchaser will be sent activation approval documents and will start receiving the benefits

of the Limited Warranty throughout the warranty period. If the Split Startup Checklist is incomplete, Purchaser will be

informed they have five days to complete the Split Startup Checklist and re-submit to WhisperKOOL. The Split Startup

Checklist will be reviewed again, and if denied, Purchaser will be informed that they have 10 business days for corrective

action. Failure to register the Product may result in loss of warranty.

D. Purchaser is responsible for the full costs of installation and any additional parts required for the proper and complete

installation of the product.

E. For  Split  Systems  returned  to  WhisperKOOL  in  accordance  with  the  terms  and  conditions  of  the  Limited  Warranty,

WhisperKOOL warrants against defects in material and workmanship as follows:

1.

LABOR

 — For a period of two (2) years commencing on the date of purchase, WhisperKOOL will, at its option and

discretion,  reimburse  up  to  $250  to  the  End  User  for  cost  incurred  for  servicing,  repairing,  removing  or  installing

warranty parts. Invoice for service must be forwarded to WhisperKOOL for assessment and  

processing.  The

Split System warranty is invalid if there is attempted repair by anyone other than an HVAC/R technician approved by

WhisperKOOL to service the Product.

2.

PARTS

 — For a period of two (2) years commencing on the date of purchase, WhisperKOOL will supply, at no charge,

new  or  rebuilt  replacement  parts  in  exchange  for  defective  parts.  Replacement  parts  are  warranted  only  for  the

remainder of the original warranty period.

3.

FREIGHT

  —  For  a  period  of  two  (2)  years  commencing  on  the  date  of  purchase,  if  after WhisperKOOL  approved

evaluation the original Product failure is determined to be the cause of a manufacturers defect, and not the cause of

an installation error or other cause, WhisperKOOL will cover at its option, freight for the replacement parts or Product.

The following part or cause of failure is not the responsibility of WhisperKOOL: 

• Improper voltage supply
• Line set with screw connectors (high end and low end)
• Leaks found at the braze points when performing pressure check
• Unit that has been charged incorrectly

PRODUCT

Split

 Cassette

 System Series 

WARRANTY INFORMATION

The Coolest Thing In Wine Storage

Page 47

Содержание PLATINUM MINI

Страница 1: ...PLATINUM SPLIT H E OWNER S MANUAL NOTICE To activate the split system warranty the installing certified HVAC R service tech must complete the split system warranty checklist and send back to WhisperK...

Страница 2: ...not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice V...

Страница 3: ...it Wiring Diagram 24V Condensing Unit Wiring Diagram Line Set Piping Diagram Preparing The Condensing Unit Condensing Unit Wiring Installing The Condensing Unit Display Layout And Specifications Contr...

Страница 4: ...KOOL Cooling System The WhisperKOOL cooling system is a specialized refrigeration system designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper s...

Страница 5: ...tat to the evaporator unit 5 You are REQUIRED to install a drain line to remove condensation from the evaporator unit fan coil unit 6 The warranty is not active until a warranty checklist has been rec...

Страница 6: ...ant the insulation is to conducting heat and the more consistent your wine cellar s temperature will be Using higher R values in insulation will lower your operating costs and unit run time R 13 is th...

Страница 7: ...y cool environment by capturing the warm air and replacing it with cool air Mounting the unit low in the room will result in a temperature variation in the room due to the unit s inability to draw war...

Страница 8: ...t If ventilation is inadequate the exhaust will heat up the area or room and adversely affect the system s ability to cool In some cases it may be advisable to install a vent fan to dissipate heat wit...

Страница 9: ...or visual damage on the bill of lading before signing Allow the condensing unit to sit for 24 hours prior to start up The condensing unit can be placed in the installation location piped and evacuate...

Страница 10: ...r unit REAR VIEW INSIDE CELLAR Option 2 Knockout for drain line Mounting keyholes 4 Knockout for wiring THROUGH THE WALL Option 1 Knockout for wiring Line set knockout Knockout for KDT unit bottle pro...

Страница 11: ...curely into bottle as seen in Figure 1 4 Place the wine bottle in your wine cellar Ensure sensor tip is fully submerged 5 To ensure a consistent temperature place bottle probe approximately three 3 fe...

Страница 12: ...e desired location to the evaporator installation location 4 Route the bottle probe cable from the desired thermostat bottle location to the evaporator unit installation location 5 Route the drain lin...

Страница 13: ...on cable inside of the evaporator unit 3 Connect the wires according to color red to red green to green and blue to blue Note The evaporator unit will not contain a yellow wire See next step for more...

Страница 14: ...ng the wires on the rear left corner of the interior of the unit 3 Locate tab on left wall of unit with female connector for bottle probe 4 Connect the bottle probe circular connector male to the circ...

Страница 15: ...te on the wall lining up the vertical lines through the sight slots 5 With a pencil mark the mounting screw holes and draw a location for the access hole on the installation template 6 Set installatio...

Страница 16: ...IT CONTINUED 12 Route power supply wires into the unit through the power knockout and install the supplied strain relief 13 Connect power supply wires to the wires located inside of the unit hot black...

Страница 17: ...ward angle to prevent burrs from falling into the pipe b Using a reamer or deburring tool remove all burrs from the cut section of the pipe F F Oblique Rough Warped 90 CONNECTING THE LINESET 3 Flare p...

Страница 18: ...and c Using a spanner grip the nut on the unit tubing PIPING EXTENSION BEYOND FLARE FORM Outer Diameter of Pipe in A in Min Max 1 4 0 0275 0 05 3 8 0 04 0 063 0 04 0 07 0 078 0 086 0 078 0 094 Flare f...

Страница 19: ...provided but required The condensation drain line tube moves excess condensation from the evaporator unit to a proper discharge location It is important for the drain line tube to be properly connect...

Страница 20: ...N AND CONFIGURATION KDT NOTE Cut hole in the location shown for routing the display cable Tools needed 5 16 drill bit 3 16 drill bit drywall saw level pencil What s included Display panel wall mount b...

Страница 21: ...the four 4 provided drywall anchors into the drywall then tap them in with a hammer until they are flush with the wall 3 Place bracket against wall aligning screw holes with drywall anchors Insert th...

Страница 22: ...ore you continue to Step 4 locate the area where the display will be mounted You may route the display wire into the housing one of three ways either through the wall or through one of the holes on th...

Страница 23: ...Cut along the perforated lines When finished remove template from wall INSTALLING THE EVAPORATOR 1 Locate the desired installation location 2 Place the external drip tray on a level surface Place a vi...

Страница 24: ...he backing from the double sided tape on the flush mount bracket 6 Align magnets with previously drilled holes Make sure the cut out portion of the bracket circled below is on the bottom Press the bra...

Страница 25: ...display panel to the magnets on the mounting bracket Make sure that the alignment tab on the back of the display panel sits in the notch on the bot tom of the bracket FLUSH MOUNT BRACKET INSTALLATION...

Страница 26: ...ACK GREEN BLACK WHITE WHITE 115V LINE 115V NEUTRAL GROUND WHITE 1 4 RED BLACK BLACK 24v Transformer BLACK WHITE YELLOW BLUE YELLOW BLUE 24V WIRES TO CONDENSING UNIT 120mm AFL Blower GREEN BLUE BROWN G...

Страница 27: ...C Field Installed LEGEND Factory Installed Blue Black Black Fan Relay Red Blue Yellow 24v Thermostat 24V Wires to Condensing Unit White Black Blue Yellow 1 4 BLACK GREEN 120mm AFL Blower WHITE 115V LI...

Страница 28: ...ellow Green Crankcase Heater Temperature Switch Compressor Run Capacitor Fan Capacitor Liquid Line Injector Temperature Switch Condenser Fan Red Gray Brown White Red White Yellow Compressor Run Capaci...

Страница 29: ...icable when the system is installed with the condensing unit at a higher elevation than the coil Reverse oil return bend Oil saving bend Suction Line Evaporator Coil Within 16 of height Downward slope...

Страница 30: ...nsing Unit systems do not utilize a solenoid valve or low pressure switch which allows the system to run like a residential HVAC system A 24V communication cable must be ran between the condensing uni...

Страница 31: ...door condensing unit per electrical code 2 Remove electrical cover plate from unit 3 Connect wiring for 24V contactor communication cable L1 L2 and Ground as identified by terminal block label 4 Leave...

Страница 32: ...combustible gas In a location that is exposed to large amounts of dust In a location exposed to a excessive amounts of salty air In a closet or small room Special Considerations For Cold Weather And O...

Страница 33: ...er and nut on the end of eachexpansion bolt 5 Thread expansion bolts through holes in mounting brackets put mounting brackets in position and hammer expansion bolts into the wall 6 Check that the moun...

Страница 34: ...w side gauge manifold knobs SLOWLY at the same time to admit nitrogen into the system until the gauge manifold reads 225 psi then close gauge manifold knobs Let pressure stand for minimum of 10 minute...

Страница 35: ...need to add additional charge and dial in the desired subcooling to achieve optimum performance Subcooling range is between 5 15 F o When charging during colder ambient temperatures below 60 F your t...

Страница 36: ...ve or equivalent Confirm that the control is displaying the correct temperature and that no alarms are present INSTALLING THE CONDENSING UNIT continued Finalizing the Installation Approximate Operatin...

Страница 37: ...50 ft Drain Line 1 2 ID clear plastic tubing not included Installation Evaporator unit is installed in the cellar Condensing unit can be installed up to 100 line feet from the evaporator unit Thermos...

Страница 38: ...menus and adjust parameters such as setpoint Fon FOF etc SET To change the setpoint press the SET button When SEt is displayed on the screen press the SET button once more Use the UP and DOWN ARROW bu...

Страница 39: ...is undergoing an Anti Frost Cycle While the Anti Frost Cycle is running dEF will be displayed on the screen See System Operation page for further details FAN The evaporator fan is running ALARM The a...

Страница 40: ...or kinked If problem persists contact Customer Service for troubleshooting information E10 Clock battery is dead Replace battery NOTE A dead clock battery will not affect the operation of your coolin...

Страница 41: ...operly constructed wine cellars retain an ample amount of humidity during the fan off cycle If however you wish to decrease the duration of the fan off cycle in order to increase the wine cellar s rel...

Страница 42: ...aulty thermostat or wiring Call Customer Service at 1 800 343 9463 Cellar temperature is too warm Possible cause Solution The temperature of the room to which the condensing unit exhausts exceeds 110...

Страница 43: ...ti Frost Cycle No action is required 2 If the system is not maintaining the correct cellar temperature this may be due to a dirty evaporator filter or coil 3 Call the installing technician to troubles...

Страница 44: ...the unit from running Contact Customer Service for troubleshooting 24V transformer in evaporator unit fan coil unit has failed Contact Customer Service for troubleshooting Evaporator fan runs continuo...

Страница 45: ...and the condenser fan will turn on but the indoor fan will continue to run for whatever length of time the customer has set The Non function may then be lengthened to allow the fan to run longer and r...

Страница 46: ...ave a safety feature that will prevent the condensing unit from cycling on and off within a short period of time During the anti short cycle the condensing unit will typically remain off for 5 7 minut...

Страница 47: ...evaporator coil be careful not to crush coil fins when cleaning clean condensing coils also 2 Remove the evaporator filter and clean with warm water 3 Ensure the condensing unit is free of debris and...

Страница 48: ...and customize your wine cooling unit Condensate Pump Kit The condensate pump kit is designed as an automatic condensate removal pump for water dripping out of our Evaporator Unit s Fan Coil Unit s dra...

Страница 49: ...period If the Split Startup Checklist is incomplete Purchaser will be informed they have five days to complete the Split Startup Checklist and re submit to WhisperKOOL The Split Startup Checklist wil...

Страница 50: ...oduct installation requirements stated herein and in the owner s manual 9 Removing the rivets from the Product s unit housing without prior authorization from WhisperKOOL voids this limited warranty 1...

Страница 51: ...nstallation error or other reason all costs including shipping will be the responsibility of the End User The following items are not covered under any warranty and are the sole responsibility of the...

Страница 52: ...orceable If any provision of these Terms and Conditions is held by a court of competent jurisdiction to be invalid illegal or otherwise unenforceable such provision will to the extent so held be deeme...

Страница 53: ...e is available Monday through Friday from 6 00 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and warranty information more effectively if you p...

Страница 54: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...

Отзывы: