DISPLAY LAYOUT
PLATINUM MINI SPECIFICATIONS
Compressor is on
Fan is on
Anti-Frost Cycle
running
Alarm is present
°
F
°
F
View/Change Setpoint
Enter User Menu
Unlock Button
(
hold for 1 sec
)
Scroll Button
Change Setpoint
55
°
F
Power On/O
ff
(hold for 5 sec)
Scroll Button
Change Setpoint
Return to Previous
Menu
D
ISPLAY
L
AYOUT
A
ND UNIT SPECIFICATIONS
Model
Mini Evaporator
(Fan Coil Unit)
Mini
H.E.
Condenser
(Air-Cooled Condensing Unit)
Fan Speed
Low
Dimensions
Refrigerant
R-134a
Condensing Unit HP
0.35 HP
Voltage Rating
120V (15-amp dedicated circuit required)
Weight (lbs)
33
50.7
Amps
0.97 Running Amps
Line Set
Liquid line 1/4" OD; Suction line 1/2" OD (less than 50ft.), 5/8" (greater than 50.ft)
Drain Line
1/2” ID clear plastic tubing(not included)
Installation
Evaporator unit is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
KDT- Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V - Customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
Medium
BTU/h ( (60°F condenser air
intake temperature)
BTU/h ( (75°F condenser air
intake temperature)
BTU/h ( (75°F condenser air
intake temperature)
1829/2436
2275/2891
1760/2326
2127/2641
1666/2141
2078/2492
Mini H.E. Condenser (Air-Cooled
Condensing Unit)
13”L x 20"W x 10.5”H
31.18"L x 10.75”W x 21.18"H
220V (15-amp dedicated circuit required)
LRA 5.3A, RLA 1.55A, FLA 1.7A
Cellar Size
1750 cu. ft.
Page 35