background image

Copyright © 2020. WhisperKOOL. All rights reserved. 

WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights 

with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of 

the USA. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any 

printed or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written 

consent of WhisperKOOL. 

Every effort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for 

printing or clerical errors. 

WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related 

hardware at any time, without notice. 

Vinothèque and WhisperKOOL are registered trademarks, and ECE is a trademark of WhisperKOOL. All rights reserved. 

Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a 

recommendation. WhisperKOOL assumes no liability with regard to the performance or use of these products.

We manufacture, test and certify 100% of our wine cooling units in  

the USA. By sourcing the best components and closely controlling our  

manufacturing processes, we can assure the highest-quality,  

lowest defect manufacturing rates in the industry. 

Conforms to ANSI/UL Std 427

Certified to CAN/CSA Std C22.2 No. 120

Содержание Ceiling Mount 4000

Страница 1: ...CEILING MOUNT ADDENDUM 2 3 2020 Ceiling Mount 4000 Ceiling Mount 8000 Ceiling Mount Twin...

Страница 2: ...not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice V...

Страница 3: ...TABLE OF CONTENTS Filter 3 Line Set Drain Tube and Electrical Connections 4 Additional Access Holes 4 2 Speed Switch 5 Insulation Blanket Installation 6 Wiring Diagrams 8...

Страница 4: ...et This includes the cavity between the ceiling joists A warm attic environment will reduce the capacity of the cooling system as the system will absorb heat from the attic in addition to the heat loa...

Страница 5: ...www whisperkool com Page 3 Ceiling Mount Addendum Washable filter is installed from the factory on the return side of the grille secured via Velcro strips FILTER...

Страница 6: ...fy there are no leaks before beginning vacuum and charging process ADDITIONAL ACCESS HOLES Top access holes 1 large hole for line set 1 small hole for electrical Note do not run electrical wiring thro...

Страница 7: ...ED SWITCH The WhisperKool Ceiling mount now comes equipped with a 2 speed fan switch Located on the electrical panel Access by removing grille and internal access panel Speed is sent from factory set...

Страница 8: ...es of the evaporator unit see illustration 5 Using a utility knife cut holes in the insulation for the line set wiring and drain line if needed 6 If necessary cut the insulation to size using the top...

Страница 9: ...ion is installed apply foil tape to all seams covering them completely 11 Inspect insulation for damage defects If damaged repair with foil tape 12 Apply cork tape or equivalent to areas where the lin...

Страница 10: ...Thermostat RC Field Installed LEGEND Factory Installed Solenoid or Compressor Relay Blue Black Black 146mm AFL Blower GREEN BLACK WHITE YELLOW BROWN GREY Capacitor BLUE 1 2 3 CONDENSATE PUMP BLACK YEL...

Страница 11: ...18 5 THERMOSTAT WIRES GOING TO SLAVE UNIT CM TWIN MASTER UNIT WIRING DIAGRAM Field Installed LEGEND Factory Installed YELLOW BLACK 146mm AFL Blower GREEN BLACK BLUE WHITE YELLOW BROWN GREY Capacitor B...

Страница 12: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...