2.2
TRANSPORT, LIFTING AND STORAGE
When lifting the generating set avoid any risk
of personal injuries, do not stand un-der the
generating set..
•
Use soft slings to avoid damage
•
On the engine are two lifting eyes, only to be
used to take the generator out of the capsule. Do
not use to lift the set including the capsule and
certainly not including the steel foundation plate !
•
After transporting the generating set check for
damage before installation.
•
Long term storage can have detrimental effects
on engine and alternator. The engine should be
put through an engine preservation procedure.
(Refer to the maintenance chapter).
•
The alternator windings tend to condense. To
minimise condensation, store the generating set
in a dry and warm storage area.
•
After removing the generating set from long term
storage perform an insulation check. (Refer to the
alternator maintenance paragraph for
procedures)
•
While the battery is stored it should be recharged
every 12 weeks.
2.3 THE
M-SC6/8/10
2.3.1 Features
This generating set includes a diesel engine which is
connected by close coupling to an alternator in a sound
attenuated capsule. The set is mounted on a steel base
frame and mounted securely on anti-vibration mounting
pads to the capsule base. All cables and hoses are guided
through the capsule’s left side. The set is not self-
contained and is only operable after proper installation
using additional accessories and installation materials.
Installation accessories are listed in the installation manual
and are available through the supplier of the genera-ting
set. The full automatic Digital Control is based on
microprocessor technology. Several automatic start/stop
functions can be programmed and monitored (refer to
Digital Diesel Control user manual).
2.3.2
Remote control
The full automatic remote control panel including 15 mtr
cable comes as standard with the M-SC6/8/10.
2.3.3 Documentation
Included in the delivery are:
•
This user manual (number: 40200351)
•
An installation manual (number: 40200361)
•
A user manual for DCC (number: 40200261).
•
A quick reference guide for DDC (number
40200275)
Not included in the standard delivery but available as
options are:
•
Parts manual; number: 40200381 (M-SC6/8)
•
Parts manual; number: 40200382 (M-SC10)
•
Workshop manual; number: 40200171 (M-
SC6/8/10)
However in this manual there is a list of important parts for
maintenance and spare parts as well as a chapter on
maintenance and problem solving.
2.3.4
Accessories included in the standard
delivery
•
Special hose connector for measuring exhaust
backpressure.
•
Expansion tank, hose and fittings.
Содержание M-SC6
Страница 17: ...INFORMATION EN M SC6 8 10 December 2010 17 2 5 15 Lay out control wiring Fig 11 Lay out control wiring ...
Страница 37: ...TROUBLE SHOOTING EN M SC6 8 10 December 2010 37 Figure 26 exploded view sound shield M SC6 8 and 10 ...
Страница 39: ...SPARE PARTS LIST EN M SC6 8 10 December 2010 39 Fig 27 Water pump type M ...
Страница 41: ...NOTES EN M SC6 8 10 December 2010 41 NOTES ...
Страница 42: ...NOTES 42 December 2010 M SC6 8 10 EN NOTES ...
Страница 43: ...NOTES EN M SC6 8 10 December 2010 43 NOTES ...