10
WhisperPower
Lithium Plus 12 V 210 Ah 340 Ah
2.4. Environmental conditions
Warning! The Lithium battery may only be used in conditions specified in this manual.
Exposing the Lithium battery to conditions outside the specified boundaries may lead to
serious damage to the product and/or the user.
Use the Lithium battery in a dry, clean, dust free, well ventilated space. Do not expose the
Lithium battery to fire or water or solvents.
When the Lithium battery is placed in an enclosed environment without air circulation, it is
advised to provide 2 ventilation holes of 100mm x 100mm each. This helps to prevent the
heat built-up.
Recommended charge temperature range*
0°C to +45°C / 32
o
F to 113
o
F
Discharging operating temperature range
-10°C to +55°C / 14
o
F to 131
o
F
Short term (<1 month) storage temperature range
-20°C to +45°C / -4
o
F to 113
o
F
Long term (>1 month) storage temperature range
-0°C to +35°C / 32
o
F to 95
o
F
Relative humidity
10-90%
Corrosion
Salt-contaminated atmosphere up to
1 mg salt per m
3
of air, at all relevant
temperatures and humidity conditions.
Applicable to equipment located in open
air and made of material subject to
corrosion.
Placement angle (continuously)
Up right
Vibrations and shocks
According UN38.3
Table 7. Environmental conditions
(*) Do not charge the Lithium battery below 0 °C / 32 F
2.4.1. Marine use
Parameter
Class
Location
Temperature
A
Machinery spaces, control rooms, accommodation, bridge
Humidity
B
All locations except as specified for location A
Vibration
A
On bulkheads, beams, deck, bridge
EMC
B
All locations including bridge and open deck
Table 8. Marine use