Figure 5-3
5-7
5.6 Over Speed Warning
If an engine over speed occurs perform the following appropriate
action
Overspeed Occurrence
Required Action
up to 110 % of the max RPM
A 50 hours inspection must be
performed immediately by a
certified A&P mechanic
111% to 120% of the max
RPM
A mandatory teardown inspection
at the factory is required
above 121% of the max RPM
No further use of the propeller is
permitted! The propeller must be
returned to the factory for
inspection.
WARNING:
Failure to adhere to these guidelines
may lead to a catastrophic propeller structural
failure. Any type of structural failure may result in
death or severe bodily injury.
5-8